Note
Action
The figure shows
Other design than Type
C
. The principle of securing the bracket
on
Type C
is the same.
xx0900000018
Secure the
bracket
on its
attachment screws
in the base.
Tip
Perform this in the following order:
•
Put the
attachment screws
in the
holes but do not tighten them yet (if
they have been removed earlier).
•
Place the
bracket
on the attachment
screws.
•
Secure the bracket with its attach-
ment screws.
4
Parts:
•
A: Base
•
B: Attachment screws (2 pcs)
•
C: Bracket
xx0900000015
Refit the
earth cables
.
5
Parts:
•
A: Earth
•
B: Distance screws
Connect the contacts on the SMB unit:
•
R1.SMB1-2
•
R1.SMB3-6
•
R2.SMB
6
How to refit the SMB unit is described in
section:
•
Refitting the SMB unit on page 226
Refit the SMB unit.
7
Continues on next page
3HAC033453-001 Revision: H
215
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.2 Refitting the complete cable harness
Continued