Installation, fan on motor axis 2
Use this procedure to install the cooling fan on motor axis 2.
Note
Action
DANGER
Turn off all:
•
electric power supply to the robot
•
hydraulic pressure supply to the robot
•
air pressure supply to the robot
Before entering the robot working area.
1
See the figure in:
•
Remove the back plate of the fanbox.
2
Place the fanbox around motor axis 1.
3
See the figure in:
•
Refit the back plate of the fanbox.
4
Fit the fanbox with two attachment screws
M6x30.
5
xx0900000405
Connect the fan connector to motor and fan.
6
Parts:
•
A: Connector, signal
•
B: Connector, power
•
C: Fan cable
•
D: Connector, fan
•
E: Cable gland
•
F: Motor cover, with fan cable
Continues on next page