Installation, fan on motor axis 1
Use this procedure to install the cooling fan on motor axis 1.
Note
Action
DANGER
Turn off all:
•
electric power supply to the robot
•
hydraulic pressure supply to the robot
•
air pressure supply to the robot
Before entering the robot working area.
1
See the figure in:
•
Remove the back plate of the fanbox.
2
See the figure in:
•
Place the fanbox around motor axis 1.
3
Refit the back plate of the fanbox.
4
See the figure in:
•
Tip
If there is a lack of space between motor and
robot, it is possible to remove part of the fanbox.
5
Align the upper part of the fan with the
lower part of the connection box.
A
B C
xx1000000124
Push the fanbox in line with the connection box.
6
Parts:
•
A: Connection box
•
B: Position where the fan shall
be aligned with connection box
•
C: Fan
Fit the fanbox with two attachment screws
M6x25.
7
Continues on next page
3HAC033453-001 Revision: H
93
© Copyright 2009-2013 ABB. All rights reserved.
2 Installation and commissioning
2.5.1 Installation of cooling fan for motors (option)
Continued