2.8.3 Customer connections on upper arm
Customer connections on upper arm
The figure shows the customer connections on the upper arm, including the optional
signal lamp that can be fitted to the armhouse.
A
B
C D
xx0800000290
Signal lamp
A
R3.H1 +, R3.H2 -
B
R2.CP
C
R2.CS
D
Power supply connections on upper arm
Customer Contact on robot base
(cable between robot and controller
not supplied)
Customer Contact
on Upper arm, R2
Customer Ter-
minal Controller
Signal name
R1.CP/CS.d1
R2.CP.A
XP6.1
CPA
R1.CP/CS.d6
R2.CP.B
XP6.2
CPB
R1.CP/CS.d3
R2.CP.C
XP6.3
CPC
R1.CP/CS.d4
R2.CP.D
XP6.4
CPD
R1.CP/CS.d1
R2.CP.E
XP6.1
CPE
R1.CP/CS.d6
R2.CP.F
XP6.2
CPF
R2.CP.G (Earth)
CPG
R1.CP/CS.d7
R2.CP.H
-
CPH
R1.CP/CS.d3
R2.CP.J
XP6.3
CPJ
R1.CP/CS.d4
R2.CP.K
XP6.4
CPK
Continues on next page