Start-up 43
FSCA-01 configuration parameters – group C (group 3)
Note:
The actual parameter group number depends on the drive
type. Group C (group 3) corresponds to:
•
parameter group
54
in ACS355
•
parameter group
52
in ACSM1, ACS530, ACS850 and
ACQ810
•
parameter group
52
in ACS880 if the adapter is installed as
fieldbus adapter A or group
55
if the adapter is installed as
fieldbus adapter B.
No.
1)
Name/Value
Description
Default
01
FBA data in1
(drive to master)
Selects the drive parameter address from
which the data is read to the DATA IN 1
register (from the server to the master). The
Modbus register address maps are explained
in chapter
Communication protocol
.
The content is defined by a decimal number in
the range of 0 to 9999 as follows:
0
= None
0
= None
Not used
101…9999
Parameter index with format
xxyy
, where
•
xx
is the parameter group number (1…99)
•
yy
is the parameter number index within
that group (01…99).
Other
Path to parameter area selection.
02…
12
FBA data in2…
FBA data in12
See parameter
01
FBA data in1
.
0
= None
1)
The number of parameters in this group may vary by drive type and drive firmware.
0
Not used
1…99 Virtual address area of drive control.
Not used with Modbus/RTU.
101…
9999
Parameter area of the drive
Summary of Contents for FSCA-01
Page 1: ... OPTION FOR ABB DRIVES CONVERTERS AND INVERTERS FSCA 01 RS 485 adapter module User s manual ...
Page 4: ......
Page 8: ...8 Table of contents ...
Page 18: ...18 About the manual ...
Page 24: ...24 Overview of the RS 485 network and the FSCA 01 module ...
Page 28: ...28 Mechanical installation ...
Page 32: ...32 Electrical installation ...
Page 68: ...68 Communication profiles ...
Page 82: ...82 Communication protocol ...