Parameterization
D184B111U02 CoriolisMaster
FCM2000
85
Parameter
Value range / input type
Note
Qm
Measure
Table
Enter
Enter
Enter
This menu can be used to measure the actual
mass flowrate while in the simulation mode.
Qm
-115 ... +115 %
float
15.00 %
Technician*
The mass flowrate value for the simulation can be
entered in percent. This menu is only displayed
when mass flowrate was selected. The allowable
range of entries is -115 % ... +115 %.
Density
Measure
Table
Enter
Enter
This menu can be used to specify how to measure
the actual mass flowrate while in simulation mode.
Enter
Technician*
Density
0.3 ... 3.7 g/ml
float
1.00 g/ml
Technician*
The density value for the simulation can be
entered. This menu is only displayed when
density was selected. The allowable range of
entries is 0.3 ... 3.7 g/cm
3
.
Temperature
Measure Table
Enter
Enter
Enter
This menu can be used to specify how to measure
the temperature while in simulation mode.
Technician*
Temp. housing
Measure
Table
Enter
Enter
Enter
This menu can be used to specify how to measure
the temperature while in simulation mode.
Technician*
Temperature
-60 ... 190 °C
float
30 °C
Technician*
The temperature value for the simulation can be
entered. This menu is only displayed when
temperature was selected. The allowable range of
entries is -60 ... 190 °C.
Temp. housing
Measure
float
20 °C
Enter
Enter
Technician*
Function
test
Technician*
HART
Transmitter
The two HART-Frequencies (1200 Hz and 2200
Hz) can be selected and transmitted.
Function
test
Technician*
HART
command
The received HART commands are displayed.
Summary of Contents for CoriolisMaster FCM2000
Page 112: ...Appendix 112 CoriolisMaster FCM2000 D184B111U02...
Page 113: ...Appendix D184B111U02 CoriolisMaster FCM2000 113...
Page 114: ...Appendix 114 CoriolisMaster FCM2000 D184B111U02...
Page 115: ...Appendix D184B111U02 CoriolisMaster FCM2000 115...
Page 116: ...Appendix 116 CoriolisMaster FCM2000 D184B111U02...
Page 117: ...Appendix D184B111U02 CoriolisMaster FCM2000 117...
Page 118: ...Appendix 118 CoriolisMaster FCM2000 D184B111U02...
Page 119: ...Appendix D184B111U02 CoriolisMaster FCM2000 119...
Page 120: ...Appendix 120 CoriolisMaster FCM2000 D184B111U02...