Installation
D184B111U02 CoriolisMaster
FCM2000
25
Pos: 24.10 /Technische Daten / Datenblatt/Durchfluss/FCM2000/Einbaubedingungen/MC2/Horizontale Einbaulage, selbstleerend @ 5\mod_1166448894656_3101.doc @ 52608 @ 5
Horizontal Installations, Self Draining
G00304
Fig. 16:
Horizontal Installations, Self Draining,
α
2 - 4°
Pos: 24.11 /Technische Daten / Datenblatt/Durchfluss/FCM2000/Einbaubedingungen/MC2/Einbau in Fallleitungen @ 5\mod_1166448947703_3101.doc @ 52629 @ 5
Installation in a Drop Line
The installation recommendation shown in Fig. 17 is only permissible
if a pipeline reduction or orifice with a smaller cross-section can be
installed to prevent the flowmeter sensor from partially draining
during the measurements.
G00305
1
2
3
4
5
Fig. 17:
Installation in a Drop Line
1
2
3
4
5
Supply reservoir
Flowmeter sensor
Orifice/pipe constriction
Valve
Product reservoir
Pos: 24.12 /======= Spaltenumbruch ======== @ 0\mod_1132937966324_3101.doc @ 3831 @
Pos: 24.13 /Technische Daten / Datenblatt/Durchfluss/FCM2000/Einbaubedingungen/MC2/Kritische Einbauorte @ 5\mod_1166449143796_3101.doc @ 52650 @ 5
Difficult Installation Conditions
The accumulation of air or gas bubbles in the meter pipe can lead to
increased inaccuracies. Fig. Fig. 18 shows critical installation con-
ditions.
Installations at the highest point in the pipeline (Figure A) can result
in the formation of air pockets which can lead to appreciable
inaccuracies.
Another difficult installation condition is immediately upstream of a
free discharge (Figure B) in a drop line.
G00306
A
B
Fig. 18:
Difficult Installation Conditions
Important:
Check whether the coordination flowmeter sensor and transmitter is
correct. Compatible devices have the same end numbers, e.g., X001
and Y001 or X002 and Y002, on the type plate.
Pressure losses
The pressure losses, at the operating conditions, depends on the
fluid and the actual flow. To calculate the pressure loss, the design
program CD-CALC is provided.
Pos: 24.14 /======= Spaltenumbruch ======== @ 0\mod_1132937966324_3101.doc @ 3831 @
Summary of Contents for CoriolisMaster FCM2000
Page 112: ...Appendix 112 CoriolisMaster FCM2000 D184B111U02...
Page 113: ...Appendix D184B111U02 CoriolisMaster FCM2000 113...
Page 114: ...Appendix 114 CoriolisMaster FCM2000 D184B111U02...
Page 115: ...Appendix D184B111U02 CoriolisMaster FCM2000 115...
Page 116: ...Appendix 116 CoriolisMaster FCM2000 D184B111U02...
Page 117: ...Appendix D184B111U02 CoriolisMaster FCM2000 117...
Page 118: ...Appendix 118 CoriolisMaster FCM2000 D184B111U02...
Page 119: ...Appendix D184B111U02 CoriolisMaster FCM2000 119...
Page 120: ...Appendix 120 CoriolisMaster FCM2000 D184B111U02...