Installation
D184B111U02 CoriolisMaster
FCM2000
35
Pos: 30 /Überschriften/1.1/1-spaltig/D - F/Elektrischer Anschluss @ 0\mod_1132739463468_3101.doc @ 3182 @ 22
4.5 Electrical
connection
Pos: 31.1 /Elektrischer Anschluss/Durchfluss/FCM2000/Konfektionierung des Signal- und Erregerstromkabels @ 7\mod_1171888514437_3101.doc @ 68621 @
4.5.1 Assembly of the Signal Cable
Cable specifications for the MC2 signal cable
The signal cable between the flowmeter primary and the converter has the following
specifications:
• Designation:
UNITRONIC
−
LI2YCY (TP)
• 6 x 2 0.22 m
2
• 2
outer
shields
• Temperature range: -30 ... 70 °C (-22 ... 158 °F)
• Loop resistance: max. 186
Ω
/km
• Inductance: ca. 0.65 mH/km
• Max. cable length: 50 m (164 ft.)
Cable specifications for the MS2 signal cable
• 5 x 2 x 0.35 mm
2
• 1
outer
shield
• Temperature range -20 ... 105 °C (-4 ... 221 °F)
• Loop resistance: max. 50
Ω
/km
• Inductance: ca. 1 mH/km
• Max. cable length: 50 m (164 ft.)
Cut to length and terminate the cable as shown.
Important
Use wire end sleeves.
G00396
80 (0,59)
65 (2,56)
15
8 (0,31)
(0,59)
Fig. 30
Summary of Contents for CoriolisMaster FCM2000
Page 112: ...Appendix 112 CoriolisMaster FCM2000 D184B111U02...
Page 113: ...Appendix D184B111U02 CoriolisMaster FCM2000 113...
Page 114: ...Appendix 114 CoriolisMaster FCM2000 D184B111U02...
Page 115: ...Appendix D184B111U02 CoriolisMaster FCM2000 115...
Page 116: ...Appendix 116 CoriolisMaster FCM2000 D184B111U02...
Page 117: ...Appendix D184B111U02 CoriolisMaster FCM2000 117...
Page 118: ...Appendix 118 CoriolisMaster FCM2000 D184B111U02...
Page 119: ...Appendix D184B111U02 CoriolisMaster FCM2000 119...
Page 120: ...Appendix 120 CoriolisMaster FCM2000 D184B111U02...