Installation
36 CoriolisMaster
FCM2000
D184B111U02
G00397
Fig. 31
4.5.2 Positioning the shield drain wire and foil shield
G00455
Fig. 32:
Insulating the signal cable and positioning the shield drain wire
1.
Remove cable insulation as described in Fig. 30.
2.
Cut the woven shield to a length of approx. 15 mm (0.59”).
3.
Remove cable drain wire and foil shield.
4.
Remove cable insulation and attach cable conductor sleeves.
5.
Wind shield core around woven shield.