Basic code
Description
Code
Product series
ACS880
Type
Regenerative wall-mounted drive. When no options are selected: IP21 (UL type 1),
cable entry from bottom, ACS-AP-W Assistant control panel with a bluetooth interface,
no EMC filter, ASC880 primary control program, Safe torque-off, coated boards, quick
installation and start-up guide.
11
Size
See section
in the technical data.
xxxx
Voltage range
380…415 V. This is indicated in the type designation label as typical input voltage level
3 ~ 400 V AC.
3
380…500 V. This is indicated in the type designation label as typical input voltage levels
3 ~ 400/480/500 V AC.
5
■
Option codes
Description
Code
IP55 (UL Type 12)
B056
Flange mounting
C135
EMC filter for 2nd environment TN (grounded) system, category C3
E200
EMC filter for second environment IT (ungrounded) system, category C3
E201
EMC filter for 1st environment TN (grounded) system, category C2
E202
Common mode filter
E208
Cable conduit entry (US/UK).
H358
No control panel
0J400
DPMP-01 door mounting kit
J410
DPMP-02 door mounting kit (surface mounting) for the panel
J413
ACS-AP-I control panel
J425
FDNA-01 DeviceNet™ adapter module
K451
FPBA-01 PROFIBUS DP adapter module
K454
FCAN-01 CANopen adapter module
K457
FSCA-01 RS-485 (Modbus/RTU) adapter module
K458
36 Operation principle and hardware description
Summary of Contents for ACS880-11
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 11 drives Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 52: ...52 ...
Page 82: ...82 ...
Page 95: ...R6 R8 IP21 R6 R8 IP55 Electrical installation IEC 95 ...
Page 103: ...R6 1 5 N m 0 5 N m Electrical installation IEC 103 ...
Page 104: ...R8 1 5 N m 0 5 0 6 N m 104 Electrical installation IEC ...
Page 116: ...R6 R8 UL Type 1 R6 R8 UL Type 12 116 Electrical installation North America NEC ...
Page 142: ...142 ...
Page 154: ... Fan arrow must point up 154 Maintenance ...
Page 160: ...160 ...
Page 181: ... Package dimensions R6 R3 R8 Technical data 181 ...
Page 202: ...R3 IP21 UL Type 1 3AXD50000045323 202 Dimension drawings ...
Page 203: ...R3 Option B056 IP55 UL Type 12 3AXD50000045322 Dimension drawings 203 ...
Page 204: ...R6 IP21 UL Type 1 3AXD50000045353 204 Dimension drawings ...
Page 205: ...R6 Option B056 IP55 UL Type 12 3AXD50000045352 Dimension drawings 205 ...
Page 206: ...R8 IP21 UL Type 1 3AXD50000047667 206 Dimension drawings ...
Page 207: ...R8 Option B056 IP55 UL Type 12 3AXD50000047667 Dimension drawings 207 ...
Page 208: ...208 ...
Page 225: ... Declarations of conformity The Safe torque off function 225 ...