Parameters 201
Defines the maximum allowed motor current.
The system sets the default value to 90% of the rated
current. If required, you can increase the parameter value
by 10%.
Note:
The maximum current range and default value
depends on the drive type.
2.88 A
0.00…3.20 A
Maximum motor current.
1 = 1 A
Selects a source that switches between two different
predefined minimum torque limit sets.
0 = minimum torque limit defined by
and maximum
torque limit defined by
are active
1 = minimum torque limit selected by
and maximum
torque limit defined by
are active
The user can define two sets of torque limits, and switch
between the sets using a binary source such as a digital
input.
The first set of limits is defined by parameters
and
. The second set has selector parameters for both
the minimum (
) and maximum (
) limits that
allows the use of a selectable analog source (such as an
analog input).
Note:
In addition to the user-defined limits, torque may be
limited for other reasons (such as power limitation). Refer
to the block diagram on page
Torque limit set 1
0 (minimum torque limit defined by
and maximum
torque limit defined by
are active).
0
Torque limit set 2
1 (minimum torque limit selected by
and maximum
torque limit defined by
are active).
1
DI1
Digital input DI1 (
, bit 0).
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
DI5
Digital input DI5 (
, bit 4).
6
No.
Name/Value
Description
Default
FbEq 16
User-defined
minimum torque
limit
0
AI1
AI2
PID
0
AI1
AI2
PID
0
1
0
1
User-defined
maximum torque
limit
ACS180 FW.book Page 201 Tuesday, March 9, 2021 2:25 PM