Parameters 169
Enabled (init at stop/
power-up)
When enabled, the motor potentiometer first adopts the
value defined by parameter
. The value can then be
adjusted from the up and down sources defined by
parameters
and
A power cycle will reset the motor potentiometer to the
predefined initial value (
).
1
Enabled (resume
always)
Enabled (init at stop/ power-up)
, but the motor
potentiometer value is retained over a power cycle.
2
Enabled (init to actual) Whenever another reference source is selected, the value
of the motor potentiometer follows that reference. After
the source of reference returns to the motor
potentiometer, its value can again be changed by the up
and down sources (defined by
and
3
Enabled (resume/init
to Actual)
, but the motor potentiometer ref
act value is retained over power cycle.
4
Motor potentiometer
initial value
Defines an initial value (starting point) for the motor
potentiometer. See the selections of parameter
0.00
-32768.00… 32767.00 Initial value for motor potentiometer.
1 = 1
Selects the source of motor potentiometer up signal.
0 = No change
1 = Increase motor potentiometer value. (If both the up
and down sources are on, the potentiometer value will not
change.)
Not selected
0.
0
Selected
1.
1
DI1
Digital input DI1 (
, bit 0).
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
DI5
Digital input DI5 (
, bit 4).
6
Supervision 1
Bit 0 of
24
Supervision 2
Bit 1 of
25
Supervision 3
Bit 2 of
26
Supervision 4
Bit 3 of
27
Supervision 5
Bit 4 of
28
Supervision 6
Bit 5 of
29
).
-
Motor potentiometer
down source
Selects the source of motor potentiometer down signal.
0 = No change
1 = Decrease motor potentiometer value. (If both the up
and down sources are on, the potentiometer value will not
change.)
For the selections, see parameter
No.
Name/Value
Description
Default
FbEq 16