Parameters 107
28.23
[0]Always off, [2]DI1, [3]DI2, [4]DI3,
[5]DI4
, [6]DI5
28.72
0.000 … 1800.000 s,
3s
28.73
0.000 … 1800.000 s,
3s
28.26
-500.00 … 500.00Hz,
5Hz
28.27
-500.00 … 500.00Hz,
10Hz
28.28
-500.00 … 500.00Hz,
15Hz
Group 30 Limits
30.11
-30000.00 … 30000.00rpm,
-1500.00rpm
30.12
-30000.00 … 30000.00rpm,
1500.00rpm
30.13
-500 … 500 Hz,
-50Hz
30.14
-500 … 500 Hz,
50Hz
30.17
depend on rating
Group 31 Fault functions
31.11
[0]not used,
[2]DI1, [3]DI2, [4]DI3, [5]DI4, [6]DI5
Group 40 Process PID set 1
40.07
[0]OFF
, [1]ON, [2]ON when drive running
40.08
[8]AI1 percent,
[9]AI2 percent
40.16
[2]Internal setpoint, [11]AI1 percent,
[12]AI2 percent
40.24
-200000.00 … 200000.00, 0
40.31
[0]Not inverted (Ref - Fbk),
[1]Inverted (Fbk - Ref)
40.32
0.01 … 100.00,
1
40.33
0.0 … 9999.0 s,
60s
Group 45 Energy efficiency
45.11
[0]Disable
, [1]Enable
Group 58 Embedded fieldbus
58.01
[0]None
, [1]ModbusRTU
58.03
0 … 255,
1
58.04
[1]4800, [2]9600,
[3]19200
, [4]38400, [5]57600, [6]76800,
[7]115200
58.05
[0]8 NONE 1
, [1]8 NONE 2, [2]8 EVEN 1, [3]8 ODD 1
58.06
[0]Enabled
, [1]Refresh settings
58.14
[0]No action,
[1]Fault
, [2]Last speed, [5]Warning
Par. No. Par. Name
Settings/Range (default value on bold)
ACS180 FW.book Page 107 Tuesday, March 9, 2021 2:25 PM