314 Additional parameter data
28.72 Freq acceleration time 1
0.000…1800.000
s
1000 = 1 s
28.73 Freq deceleration time 1
0.000…1800.000
s
1000 = 1 s
28.74 Freq acceleration time 2
0.000…1800.000
s
1000 = 1 s
28.75 Freq deceleration time 2
0.000…1800.000
s
1000 = 1 s
28.76 Freq ramp in zero source
-
-
1 = 1
28.82 Shape time 1
0.000…1800.000
s
1000 = 1 s
28.83 Shape time 2
0.000…1800.000
s
1000 = 1 s
28.92 Frequency ref act 3
-500.00…500.00
Hz
100 = 1 Hz
28.96 Frequency ref act 7
-500.00…500.00
Hz
100 = 1 Hz
28.97 Frequency ref unlimited
-500.00 … 500.00
Hz
100 = 1 Hz
30 Limits
30.01 Limit word 1
0000h…FFFFh
-
1 = 1
30.02 Torque limit status
0000h…FFFFh
-
1 = 1
30.11 Minimum speed
-30000.00…30000.00
rpm
100 = 1 rpm
30.12 Maximum speed
-30000.00…30000.00
rpm
100 = 1 rpm
30.13 Minimum frequency
-500.00…500.00
Hz
100 = 1 Hz
30.14 Maximum frequency
-500.00…500.00
Hz
100 = 1 Hz
30.17 Maximum current
0.00…30000.00
A
100 = 1 A
30.18 Torq lim sel
-
-
1 = 1
30.19 Minimum torque 1
-1600.0…0.0
%
10 = 1%
30.20 Maximum torque 1
0.0…1600.0
%
10 = 1%
30.21 Min torque 2 source
-
-
1 = 1
30.22 Max torque 2 source
-
-
1 = 1
30.23 Minimum torque 2
-1600.0…0.0
%
10 = 1%
30.24 Maximum torque 2
0.0…1600.0
%
10 = 1%
30.26 Power motoring limit
0.00…600.00
%
100 = 1%
30.27 Power generating limit
-600.00…0.00
%
100 = 1%
30.30 Overvoltage control
0…1
-
1 = 1
30.31 Undervoltage control
0…1
-
1 = 1
30.35 Thermal current limitation
0...1
-
1 = 1
30.36 Speed limit selection
-
-
1 = 1
30.37 Min speed source
-
-
1 = 1
30.38 Max speed source
-
-
1 = 1
31 Fault functions
31.01 External event 1 source
-
-
1 = 1
31.02 External event 1 type
0…1
-
1 = 1
31.03 External event 2 source
-
-
1 = 1
31.04 External event 2 type
0…1
-
1 = 1
31.05 External event 3 source
-
-
1 = 1
31.06 External event 3 type
0…1
-
1 = 1
31.07 External event 4 source
-
-
1 = 1
No.
Name
Type
Range
Unit
FbEq32