06 MECHANICAL INSTALLATION
3BHS206977 E01 REV H
ACS1000I AIR-COOLED
USER MANUAL
6.6
Installing the fans
Fan units are installed over the four cutouts in the drive roof (Fig. 6-4). The two cutouts on the
left are for large or small fans with an additional base plate and the two cutouts on the right
are only for small fans.
Figure 6-4: Cutouts in drive roof - back (
A
) and front (
B
)
Drives without fan redundancy have two fans (Fig. 6-5), either two large fans or one large and
one small fan.
Figure 6-5: Standard fan installation
Drives with redundancy have one of the following fan configurations:
(1) Cutouts for large or small fans
(2) Cutouts for small fans
(3) Shock absorbers for fan unit
(4) Openings for fan motor cable
(5) Holes for fan-mounted shock absorbers
1
2
2
1
4
4
3
5
A
B
Summary of Contents for ACS1000i air-cooled
Page 1: ... MEDIUM VOLTAGE AC DRIVES ACS1000i air cooled User manual ...
Page 3: ...Contents ACS1000i air cooled User manual ...
Page 5: ... 01 About this manual 01 5 16 ...
Page 16: ......
Page 17: ... 02 Important safety information 02 17 28 ...
Page 28: ......
Page 29: ... 03 Power electronics and cabinet features03 29 56 ...
Page 57: ... 04 Control system 04 57 70 ...
Page 71: ... 05 Transportation storage and disposal05 71 78 ...
Page 78: ......
Page 79: ... 06 Mechanical installation 06 79 88 ...
Page 88: ......
Page 89: ... 07 Electrical installation07 89 104 ...
Page 105: ... 08 Commissioning 08 105 110 ...
Page 110: ......
Page 111: ... 09 Operation 09 111 124 ...
Page 125: ... 10 CDP control panel 10 125 148 ...
Page 149: ... 11 Preventive and corrective maintenance 11 149 172 ...
Page 173: ......