Cleaning the interior of the cabinet
WARNING!
Follow the safety instructions, page
. Ignoring the
instructions can cause physical injury or death, or damage to the
equipment.
WARNING!
Use a vacuum cleaner with antistatic hose and nozzle. Using a
normal vacuum cleaner creates static discharges which can damage circuit
boards.
1. Ensure that the drive is disconnected from the power line and all other precautions
described under
Safety in installation and maintenance
on page
have been taken
into consideration.
2. When necessary, clean the interior of the cabinet with a soft brush and a vacuum
cleaner.
Every 9 years.
Every 6 years
if ambient
temperature in continuous
operation is over 40 °C
(104 °F).
Main cooling fan change
See section
on page
.
Every 6 years
Every 3 years
if the ambient
temperature is 40 °C (104 °F)
or cyclic heavy load or
continuous nominal load.
Change of DC circuit
electrolytic capacitors and
discharging resistors
Contact ABB.
Every 9 years
JINT board and flat cable
change, BFPS board, BGAD
board and JGDR board
change
Contact ABB.
Every 9 years
Control panel battery
replacement.
The battery is housed on the rear of
the control panel. Replace with a new
CR 2032 battery.
Summary of Contents for ACQ810-04
Page 4: ......
Page 10: ...10 ...
Page 22: ...22 Introduction to the manual ...
Page 42: ...42 Planning the cabinet installation ...
Page 75: ...Installation 75 Assembly drawing frame G1 ...
Page 76: ...76 Installation Assembly drawing frame G2 ...
Page 83: ...Installation 83 3 6a 6b 5 4 8 4 8 6a 6b 7a 7b 7b ...
Page 84: ...84 Installation Assembly drawing of installing the drive module to the cabinet frame G1 ...
Page 85: ...Installation 85 Assembly drawing of installing the drive module to the cabinet frame G2 ...
Page 100: ...100 Installation ...
Page 104: ...104 Installation checklist ...
Page 106: ...106 Start up ...
Page 108: ...108 Fault tracing ...
Page 128: ...128 Technical data ...
Page 130: ...130 Dimension drawings Frame G1 Drive module dimensions ...
Page 131: ...Dimension drawings 131 Frame G1 Drive module dimensions with optional cabling panels H381 ...
Page 132: ...132 Dimension drawings ...
Page 133: ...Dimension drawings 133 Frame G1 Cabling panels H381 installed into a Rittal TS 8 cabinet ...
Page 134: ...134 Dimension drawings Frame G2 Drive module dimensions ...
Page 135: ...Dimension drawings 135 Frame G2 Drive module dimensions with optional cabling panels H381 ...
Page 136: ...136 Dimension drawings ...
Page 137: ...Dimension drawings 137 Frame G2 Cabling panels H381 installed into a Rittal TS 8 cabinet ...
Page 138: ...138 Dimension drawings Bottom plate ...
Page 142: ...142 du dt filters ...
Page 144: ...3AUA0000120538 Rev A EN 2012 06 27 Contact us www abb com drives www abb com drivespartners ...