Operating Instructions — Analyze and Process Data
4500 Series of Instruments
System User Guide
78 of 138
RUO-IDV-05-0264-A
•
To skip to the next sample in the data file, click the icon with the arrow pointing to the
right.
•
To skip to a non-sequential sample, click the icon with the arrow curving to the right.
•
In the
Select Sample
dialog, in the
Sample
list, select the sample.
•
To go to the previous sample in the data file, click the icon with the arrow pointing to
the left.
Show Experimental Conditions
The experimental conditions used to collect data are stored in the data file with the results. The
information contains the details of the acquisition method used: the MS acquisition method (that
is, the number of periods, experiments and cycles) including instrument parameters, and HPLC
device method (LC pump flow rate). In addition, it also contains the MS resolution and mass
calibration tables used for the sample acquisition.
shows the software functionality
available when the user views the file information.
•
Click
Explore
>
Show
>
Show File Information
.
The File Information pane opens below the graph.
Note:
If data is acquired from more than one sample into the same .wiff file, the file
information pane will not refresh automatically as the user scrolls through the samples.
Close the file information pane and then reopen it to view the details for the next sample
in the .wiff file.
Tip!
To create an acquisition method from the file information pane, right-
click the file information pane and then click
Save Acquisition Method.
Table 10-1 Right-Click Menu for Show File Information Pane
Menu
Function
Copy
Copies the selected data.
Paste
Pastes data.
Select All
Selects all the data in the pane.
Save To File
Saves data in an .rtf file.
Font
Changes the font.
Save Acquisition Method
Saves the acquisition method as .dam file.
Save Acquisition Method to
CompoundDB
Opens the
Specify Compound Information
dialog.
Select the IDs and molecular weights to be saved in the
compound database.
Delete Pane
Deletes the pane.
Summary of Contents for QTRAP 4500 LC/MS/MS system
Page 4: ...Revision Log 4500 Series of Instruments System User Guide 4 of 138 RUO IDV 05 0264 A ...
Page 22: ...Hazards Symbols 4500 Series of Instruments System User Guide 22 of 138 RUO IDV 05 0264 A ...
Page 130: ...Troubleshooting 4500 Series of Instruments System User Guide 130 of 138 RUO IDV 05 0264 A ...
Page 136: ...4500 Series of Instruments System User Guide 136 of 138 RUO IDV 05 0264 A ...