Chapter 4 19” Standard Cabinet Installation
3. Cabinet Fixation
As shown in
Figure 33
, press the pressure plate on the cabinet
footing, place the insulated tube. At last fix the cabinet with flat
washer, spring washer and blot. The fastening torque has to
reach 45Nm. The pressure plate is attached with an insulated
rubber pad. Pressure plate and insulated pad are shown in
Figure 34
.
F
IGURE
33 F
IX
C
ABINET
1.
Bolt M12×30
2.
Spring Washer
3.
Flat Washer
4.
Insulated Tube
5.
Pressure Plate
6.
Footing
7.
Adjusting Base
F
IGURE
34 P
RESSURE
P
AD AND
I
NSULATED
R
UBBER
P
AD
1.
Pressure Plate
2.
Insulated Pad
3.
Insulated Tube
4. Insulation Test
Modify the multimeter to resistance grade. Use the two mea-
suring heads to touch the cabinet earthing point and expansion
bolt. Measure their resistance. Continue with the next step if
Confidential and Proprietary Information of ZTE CORPORATION