Positioning Adjustable Base
Make sure of base installation position as per standard dimensions
and cabinet dimensions given in layout drawings. Measure the
marking points with the tape and mark out two straight lines with
a distance of 610mm that are parallel with benchmark.
1. Define for the position of installation holes on two lines as per
the design. With reference to them, mark out installation holes
for other bases. Verify measurement after marking of all in-
stallation holes to avoid mistake and make sure that all mea-
surements are correct.
Position holes of single cabinet are shown in
Figure 14
and .
F
IGURE
14 P
OSITION OF
S
INGLE
C
ABINET
I
NSTALLATION
1.
Equipment room wall
2.
M12 expand bolt installation
hole
3.
Adjustable base
4.
Cabinet outline
5.