Chapter 7 External Cable Installation
Note:
The contents on two labels on both ends of a power cable must
be opposite to each other.
For example, the contents filled in the L area of label at one
end must be consistent with those filled in R area of the label
at other end.
�
Optical Fiber Label
The structure of the fiber engineering label is shown in
Figure
88
.
F
IGURE
88 S
TRUCTURE OF
O
PTICAL
F
IBER
The meanings of fiber engineering label are shown in
Figure
89
.
F
IGURE
89 M
EANING OF
O
PTICAL
F
IBER
Both sides of the fiber label are marked with L and R.
�
When label is pasted on fiber at the ZXR10 8900 side, the
row No., column No. and layer of fiber in the cabinet at
the side of the connected remote optical interface device
as well as the fiber No. must be filled in the R area of the
label.
In this case, the row No. and column No. of ZXR10 8900
where the fiber is located, the fiber’s layer No. and serial
number must be filled in the L area of the label.
�
When the label is pasted at the side of the equipment
buyer’s optical interface device, the contents in the label
must be opposite to those in label at the ZXR10 8900 side.
�
Coaxial Cable Label
The structure of a coaxial cable label is shown in
Figure 90
.
Confidential and Proprietary Information of ZTE CORPORATION
93