Page 39
AquaLink
®
M8 | Installation Manual
Page 38
AquaLink
®
M8 | Installation Manual
S2 DIP Switch #
OFF
ON
1
The AquaLink M8 will be able to control a
Solar Heating system (If a solar sensor is
connected to the solar sensor input).
The AquaLink M8 will be able to control a Heat
Pump. (The AquaLink M8 will not be able to control
a Solar Heating system.)
2
NOT USED
3
NOT USED
4
NOT USED
9.3 DIP Switch Settings for Pool or Spa Only
S1 DIP Switch #
OFF
ON
1
AUX1= any equipment
AUX1= Pool Cleaner
2
AUX2= any equipment
AUX2= Low Speed for a two-speed filter pump.
Filter pump circuit becomes High Speed.
3
AUX3= any equipment
No change
4
Heater cool down operates.
Heater cool down disabled.
5
Normal operation
Factory adjustment- when this switch is on, tem-
perature delays are eliminated and solar tem-
perature is displayed.
Do not leave this switch in the ON position.
6
Spare
No change
7
Spare
No change
8
After thermostat setting has been reached,
heater will remain OFF for 3 minutes.
Heat Pump installed; after thermostat setting
has been reached, heater will remain OFF for 5
minutes.
S2 DIP Switch #
OFF
ON
1
The AquaLink M8 will be able to control a
Solar Heating system (If a solar sensor is
connected to the solar sensor input).
The AquaLink M8 will be able to control a Heat
Pump. (The AquaLink M8 will not be able to con-
trol a Solar Heating system.)
2
NOT USED
3
NOT USED
4
NOT USED