Page 35
AquaLink
®
M8 | Installation Manual
Page 34
AquaLink
®
M8 | Installation Manual
Section 8. Power Center Wiring Diagram for Combos and Onlys
IMPORTANT INSTALLATION INSTRUCTIONS:
Enclosure: Rainproof (Type 3R, IPX3) suitable for swimming pool/spa applications.
1. Installation must be by a qualified electrician and must comply with all national, state, and local codes.
2. Power Center must be mounted outside of the pool zone, at least 3.5m (11.5ft) away from the inside
edge of the pool.
3. Install to provide drainage of compartments for electrical components.
4. After wiring, install panels over wiring compartments and keep Power Center door closed.
5. For indoor or outdoor use.
To reduce the risk of injury, do not
permit children to use this product
unless they are closely supervised
at all times. Water temperature in
excess of 38°C may be injurious to
your health
.
WARNING
CAUTION
Read Installation Manual completely
before installing. This product must
be wired in accordance with the
Installation Manual.
219 Woodpark Road,Smithfield, NSW AU 2164
111 Indian Drive,Keysborough, VIC AU 3173
For technical information call Zodiac Group Australia (part of the Fluidra Group) on 1300 763 021
Red Black Red Black Red Black
S1
S2
RESET
SERVICE
TIME OUT
FIL
TER PUM
P
AUX
1
AUX
2
AUX
3
AUX
4
AUX
5
AUX
6
AUX
7
RS6 & RS8 ONLY
RS8 ONLY
HEATER
SOLAR
POOL MODE
SPA MODE
SPA DRAIN
SPA FILL
AUTO
6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
4 3 2 1 4 3 2 1
Red Black Green White Brown Blue
Not
Used
Not
Used
Green
Black Red
Yellow
Green
Black Red
Yellow
To Sensors and Heater
(green terminal bar)
To Spa Side
(black terminal bar)
RS485 Network
(red terminal bar)
F. PumpAux. 1 Aux. 2 Aux. 3
Relay Sockets (24 VDC output)
Aux. 4 Aux. 5 Aux. 6 Aux. 7
Cleaner J
VA
Solar Pump
Relay Sockets
(24 VDC output)
JVA Sockets
(24VAC output)
Intake J
VA
Return J
VA
Solar J
VA
Elect. Heater
Spare
Service Controller Connector
Low Voltage Heater
Solar Sensor
Freeze/Air Sensor
Water Temp Sensor
Network Connectors
Connect red four-pin connectors
from Controllers or Remotes
S2 DIP SWITCH SETTINGS
Factory Setting
OFF
Solar Heat Priority
Not Used
Not Used
Not Used
#
1
2
3
4
When Turned
ON
Heat Pump Priority
Not Used
Not Used
Not Used
When Turned
ON
Cleaner
2 SPD Filter Pump
Spa Spillover
Disabled
See Manual
Spare Aux (Spa Mode)
See Manual
Heat Pump
S1 DIP SWITCH SETTINGS
Factory Setting
OFF
Aux1
1 SPD Filter Pump
Aux 3 Relay
Cool Down
Normal
Spare Aux (Pool Mode)
See Manual
Gas Heater
#
1
2
3*
4
5
6*
7
8
* Note that S1-3 and S1-6 operate with Pool
and Spa Combo Only
.
Fluidra Australia Pty Ltd
ABN: 97 007 284 504
230-240 VAC Po
wer
10 Amp
10 Amp
10 Amp
10 Amp
10 Amp
10 Amp
15 Amp
15 Amp
LABEL592
POWER CENTER ENCLOSURE
WARNING
PREVENT ELECTROCUTION
Power Supply for Power Center Board: 230-240 VAC, 50/60 Hz, 3 Amps (Use 3.3 mm wire min.)
Contact Rating (high voltage): 10 Amps per outlet @ 230-240 VAC, 50/60 Hz, 2 HP @ 240 VAC (Channels 1,2,3,5,6,7)
Contact Rating (high voltage): 15 Amps per outlet @ 230-240 VAC, 50/60 Hz, 3 HP @ 240 VAC (Channels 4,8)
Contact Rating (low voltage): 1 Amp @ 24 VAC
Max. Total Amps for All Loads: 90 Amps
Important: Use raintight conduit hubs on side knock-outs. This control is not provided with integral GFCI protection for the lighting circuit. When
this control is used to power or switch an underwater luminaire, suitable GFCI protection shall be provided in the field. For load connections,
use COPPER conductors ONLY, sized on the basis of 60°C ampacity, but rated min. 75°C. For indoor or outdoor use.
DISCONNECT ALL SUPPLY
CONNECTIONS BEFORE SERVICING
THIS UNIT. THIS APPLIANCE HAS
UP TO 2 SUPPLY CONNECTIONS.
Use with AquaLink
®
M8 (RS/PDA)
Series Controllers Only.
AquaLink
®
M8 Wiring Diagram
230-240 VAC Po
wer
10 Amp
10 Amp
10 Amp
10 Amp
10 Amp
10 Amp
15 Amp
15 Amp
Line 1
Line 2
Freeze/Air Solar Sensor
Pool Temp. Sensor
Red Black Red Black
Spa Temp. Sensor
Pool Low Voltage Heater
Adjustable Fr Sensor
Red Black
RESET
SERVICE
TIME OUT
FIL
TER PU
MP
AU
X 1
AU
X 2
AU
X 3
AU
X 4
AU
X 5
AU
X 6
SPA PUMP
AUTO
6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
4 3 2 1 4 3 2 1
Re
d
Blac
k
Gree
n
Whit
e
Brow
n
Blu
e
Gree
n
Blac
k
Re
d
Yello
w
Gree
n
Blac
k
Re
d
Yello
w
To Sensors, etc.
(green terminal bar)
To Remote
(brown terminal bar)
To Controller
(red terminal bar)
F. Pum
p
Aux.
1
Aux.
2
Aux.
3
Relay Sockets (24 VDC output)
Aux.
4
Aux.
5
Aux.
6
Spa Pump
Cleaner
JV
A
Solar Pum
p
Intake
JV
A
Return
JV
A
Solar
JV
A
Spar
e
Connect red four-pin connector
to Multiplex Board
For Optional Multiplex PCB
POOL HEATER SPA HEATER
SOLAR
Spa Heate
r Interface Board
(Dual Heaters Only)
Relay Sockets
(24 VDC output)
JVA Sockets
(24 AC output)
V
Service Controller Connector
S2 DIP SWITCH SETTINGS
Factory Setting
OFF
Solar Heat Priority
Not Used
Not Used
Not Used
#
1
2
3
4
When Turned
ON
Heat Pump Priority
Not Used
Not Used
Not Used
When Turned
ON
Cleaner
2 SPD Filter Pump
Spa Spillover
Disabled
See Manual
Spare Aux (Spa Mode)
See Manual
Heat Pump
S1 DIP SWITCH SETTINGS
Factory Setting
OFF
Aux1
1 SPD Filter Pump
Aux 3 Relay
Cool Down
Normal
Spare Aux (Pool Mode)
See Manual
Gas Heater
#
1
2
3*
4
5
6*
7
8
* Note that S1-3 and S1-6 operate with Pool
and Spa Combo Only
.