Page 37
AquaLink
®
M8 | Installation Manual
Page 36
AquaLink
®
M8 | Installation Manual
FACTORY SETTING IS WITH
ALL DIP SWITCHES OFF
S1
S2
RESET
SERVICE
TIME OUT
FIL
TER PUM
P
AUX
1
AUX
2
AUX
3
AUX
4
AUX
5
AUX
6
AUX
7
RS6 & RS8 ONLY
RS8 ONLY
HEATER
SOLAR
POOL MODE
SPA MODE
SPA DRAIN
SPA FILL
AUTO
6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
4 3 2 1 4 3 2 1
1
OFF ON
3
4
5
6
7
8
2
1
2
3
4
S1
S2
Figure 34. Factory DIP Switch Settings
9.2 DIP Switch Settings for Pool and Spa Combination
S1 DIP Switch #
OFF
ON
1
AUX1= any equipment
AUX1= Pool Cleaner
2
AUX2= any equipment
AUX2= Low Speed for a two-speed filter pump.
Filter pump circuit becomes High Speed.
3
AUX3= any equipment
AUX3= Spa Spillover effect- Combination controls
only.
4
Heater cool down operates.
Heater cool down disabled.
5
Normal operation
Factory adjustment- when this switch is on, temper-
ature delays are eliminated and solar temperature
is displayed.
Do not leave this switch in the ON position.
6
Spare Aux activates with Filter Pump
when Spa OFF.
No change on Revision "HH" or older PPD. With
revision "I" or newer, Spare AUX operation is re-
versed.
7
Spare
No change on Combination or Only Controls.
8
After thermostat setting has been
reached, heater will remain OFF for three
(3) minutes.
Heat Pump installed; after thermostat setting has
been reached, heater will remain OFF for five (5)
minutes.