Page 23
AquaLink
®
M8 | Installation Manual
Page 22
AquaLink
®
M8 | Installation Manual
arrow keys to highlight the desired PUMP, then press
SELECT. Use the UP/DOWN arrow keys to highlight
either GENERAL LABELS or CUSTOM LABELS and
then press SELECT.
4.3.6
Default Preset Speed Labels (RS
Combo and RS only)
When a pump is configured for FILTRATION, the
speed presets will be labeled as shown in the table
below. The presets can be relabeled.
Default Labels when Pump is configured for
FILTRATION
PRESET #
POOL/SPA
COMBO
POOL/SPA
ONLY
SPEED
(RPM)
1
POOL
POOL
1725
2
SPA
SPEED2
2750
3
SPEED3 or
CLEANER
(if dip S1-1 is
on)
SPEED3 or
CLEANER
(if dip S1-1 is
on)
2750
4
SPEED4 or
SPILLOVER
(if dip S1-3 is
on)
SPEED4
2750
5
POOL HEAT
TEMP1
2250
6
SPA HEAT
TEMP2
2250
7
SOLAR HEAT
(if dip S1-7 is
on) or HEAT-
PUMP
(if dip S1-7 is
on) or SPEED7
SOLAR HEAT
(if dip S1-7 is
on) or HEAT-
PUMP
(if dip S1-7
is on) or
SPEED7
2750
8
INFLOOR
INFLOOR
2750
4.3.7
Preset 1:
The default label for preset #1 is POOL. This label is
tied to the pool filtration mode. Anytime the pool pump
is supposed to turn on, this preset is selected.
4.3.8
Preset 2:
On combo systems the default label for preset #2
is SPA. This label is tied to the spa filtration mode,
anytime the spa pump is supposed to turn on, this preset
is selected.
4.3.9
Preset 3:
On combo systems, if dip switch S1-1 is ON, then the
default label for this preset is CLEANER. Anytime
the cleaner mode is turned on the pump will run at the
speed setting of this preset.
On a combo system, if dip switch S1-1 is OFF, then the
default label for this preset is SPEED3.
4.3.10 Preset 4:
If dip switch S1-3 is ON, then the default label for this
preset is SPILLOVER. Anytime the spillover mode is
turned on the pump will run at the speed setting of this
preset.
If dip switch S1-3 is OFF, then the default label for this
preset is SPEED4.
4.3.11 Preset 5:
On pool/spa combo systems the default label is POOL
HEAT. When the pool heater is enabled the pump will
run at this speed.
On pool/spa only systems the default label is TEMP1.
When the pump is running and the heater set point
TEMP1 is enabled, then the pump will run at this preset.
4.3.12 Preset 6:
On pool/spa combo systems the default label is SPA
HEAT. When the system is in the SPA mode and the
SPA HEATER is enabled then the pump will run at this
speed.
RECOMMENDED SETTINGS FOR THE SYSTEM ID DIP SWITCHES
Communication
Channel
DIP SW 1
(Weight 1)
DIP SW 2
(Weight 2)
DIP SW 3
(Weight 4)
DIP SW 4
(Weight 8)
DIP SW 5
(Weight 16)
DIP SW 6
(Weight 32)
DIP SW 7
(Weight 64)
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
OFF