Page 15
AquaLink
®
M8 | Installation Manual
Page 14
AquaLink
®
M8 | Installation Manual
Figure 13. Standard JVA Mounting
A
B (Common Port)
C
3.5.2
Actuator Mounting
NOTE
: If valves are plumbed and mounted in standard
positions, there is no need to adjust the actuator cams.
JVAs may be mounted onto valves in any of the four (4)
positions shown below.
C
C
A
Figure 14. JVA Mounting Positions
B
C
A
B
III
II
I
IV
A
A
B
B
C
1. Unscrew the locking knob by turning the knob
counterclockwise. Remove the locking knob and valve
handle (see Figure 15).
2. For standard valves, remove the four (4) large Phillips
head screws from the valve. The location of the screws
you remove will determine how the actuator will be
mounted (see Figure 15). When installing the large 3”
valve, it is not necessary to remove any screws.
Figure 15. Remove Locking Knob and Lid Screws
Remove Locking
Knob and Handle
Remove the 4 Large
Phillips Head Screws
3. Turn the actuator over to see into the actuator shaft.
There are four (4) “teeth” inside of the shaft. Align with
the smallest slot on the valve (see Figure 5).
4. Place the actuator onto the valve.
5. Rotate the actuator while keeping the two shafts engaged
until the screw holes on the actuator legs align with the
empty screw holes (from step 2) in the valve (see Figure
6).
6. Use the four (4) large 2” Phillips head screws (included)
to secure the JVA to the valve.
7. Put the valve handle on the actuator shaft. Put the knob
on the shaft and tighten (finger tighten only).
Figure 16. Actuator Mounting
Place actuator on valve so smallest tooth
aligns with smallest slot.
Smallest Slot
Actuator
Bottom
Smallest Tooth
Figure 17. JVA Synchronization, Example
Suction
Return
Spa
Spa
Pool
Pool
3.5.3
Synchronization JVAs
If the valve is plumbed in the
Standard Plumbing
position
and the actuator is mounted in
Standard Mounting
position,