MENU/HELP > SET TEMP >MAINTAIN
In the SET TEMP menu, highlighting MAINTAIN and
pressing SELECT will turn on (or off) the MAINTAIN
function. MAINTAIN will run the pump for the
chosen body of water to keep the water at the desired
temperature. If this function is on, as long as the heater/
chiller is enabled for that body of water, the system will
automatically turn on the pump every couple of hours
for just enough time to test the water temperature. If the
temperature meets the set point, the pump will return to
off. If the measured temperature is different than the set
temperature, the pump will stay on and the heater/chiller
will operate long enough to bring the water to the set
temperature.
JANDY AquaLink RS
FILTER PUMP OFF
AIR 79°
06/26/04 MON
6:00 PM
EQUIPMENT ON/OFF
ONETOUCH ON/OFF
MENU / HELP
Page Up
Page Down
BACK
UP
Button
DOWN
Button
SELECT
Button
Heater LED
Green - Heater Enabled or
up to temperature
Red - Heater on and firing
Figure 28. OneTouch Control Panel Buttons
4.
Maintain Temperature Hours
MENU/HELP > SET TEMP >HOURS
Sets the desired time when this function will activate
(default setting is 12AM to 12AM; 24 hours a day).
Highlight HOURS and press SELECT. Use the UP or
DOWN buttons to change the HOURS the system will
maintain the set temperature.
4.1.4
Label Auxiliary Functions
MENU/HELP > SYSTEM SETUP > LABEL AUX > AUX 1-X >
CHOOSE LABEL TYPE > CHOOSE LABEL
Highlight MENU/HELP and press SELECT. Highlight
SYSTEM SETUP and press SELECT. Highlight
LABEL AUX and press SELECT. Highlight the
AUX you want to label and press SELECT. Highlight
GENERAL, LIGHT, WATERFALL or CUSTOM
LABEL and press SELECT. Choose a name within
these categories by using the UP or DOWN button or
the PAGE UP or PAGE DOWN button, press SELECT
when you find the correct name. Choose CUSTOM to
type in your own names.
NOTE
The Auxiliary labels AIR BLOWER and FILL
LINE have an automatic 30 minute runtime.
To change this setting, refer to the DEVICE
RUNTIME feature.
If DIP switch S1-1,2 or 3 are on, auxiliaries 1,
2 and 3 are labeled CLEANER, LOW SPEED
and SPILLOVER respectively and cannot be
relabeled.
4.1.5
Set Freeze Protection
MENU/HELP > SYSTEM SETUP > FREEZE PROTECT > SET
TEMP VALUE > SELECT FREEZE PROTECT DEVICE
Highlight MENU/HELP and press SELECT. Highlight
SYSTEM SETUP and press SELECT. Highlight
FREEZE PROTECT and press SELECT. Use the UP
or DOWN button to change the temperature. Once the
temperature is set press the SELECT button to move to
the next screen to assign freeze protection to a selected
piece of equipment. Highlight a device and press
SELECT. “X” means the device has been assigned.
NOTE
The filter pump is always assigned to freeze
protection.
4.1.6
Assign JVAs
MENU/HELP > SYSTEM SETUP > ASSIGN JVAs > SELECT JVA
Highlight MENU/HELP and press SELECT. Highlight
SYSTEM SETUP and press SELECT. Highlight
ASSIGN JVA and press SELECT. Highlight the JVA
you wish to assign and press SELECT.
NOTE
If a solar sensor is installed, the solar JVA will
automatically be assigned and will be marked
as USED.
4.1.7
Seasonal Adjust
MENU/HELP > SYSTEM SETUP > SEASONAL ADJ > SELECT
FILTRATION/SPRINKLERS/FILL LINE/CLEANER
Highlight MENU/HELP and press SELECT. Highlight
SYSTEM SETUP and press SELECT. Highlight
SEASONAL ADJ and press SELECT. Use the
UP/DOWN BUTTON TO choose FILTRATION,
SPRINKLERS, FILL LINE, and CLEANER, then press
SELECT.
NOTE
FILL LINE will be displayed on the screen only
if an AUX has been assigned to fill the label.
CLEANER will be displayed on the screen only
if DIP switch S1-1 is ON. AQUAPURE will be
displayed only if a chlorine generator is attached
to the system.