AquaLink

®

 M8  |   Installation Manual

Page 20

AquaLink

®

 M8  |   Installation Manual

MENU/HELP > SET TEMP >MAINTAIN

In the SET TEMP menu, highlighting MAINTAIN and 

pressing SELECT will turn on (or off) the MAINTAIN 

function. MAINTAIN will run the pump for the 

chosen body of water to keep the water at the desired 

temperature. If this function is on, as long as the heater/

chiller is enabled for that body of water, the system will 

automatically turn on the pump every couple of hours 

for just enough time to test the water temperature. If the 

temperature meets the set point, the pump will return to 

off. If the measured temperature is different than the set 

temperature, the pump will stay on and the heater/chiller 

will operate long enough to bring the water to the set 

temperature.

JANDY AquaLink RS

FILTER PUMP OFF

AIR 79°

06/26/04 MON

6:00 PM

EQUIPMENT ON/OFF

ONETOUCH ON/OFF

MENU / HELP

Page Up

Page Down

BACK

UP

Button

DOWN

Button

SELECT

Button

Heater LED

Green - Heater Enabled or

up to temperature

Red - Heater on and firing

Figure 28.  OneTouch Control Panel Buttons

4.

  Maintain Temperature Hours

MENU/HELP > SET TEMP >HOURS

Sets the desired time when this function will activate 

(default setting is 12AM to 12AM; 24 hours a day). 

Highlight HOURS and press SELECT. Use the UP or 

DOWN buttons to change the HOURS the system will 

maintain the set temperature.

4.1.4 

Label Auxiliary Functions

MENU/HELP > SYSTEM SETUP > LABEL AUX > AUX 1-X > 

CHOOSE LABEL TYPE > CHOOSE LABEL

Highlight MENU/HELP and press SELECT. Highlight 

SYSTEM SETUP and press SELECT. Highlight 

LABEL AUX and press SELECT. Highlight the 

AUX you want to label and press SELECT. Highlight 

GENERAL, LIGHT, WATERFALL or CUSTOM 

LABEL and press SELECT. Choose a name within 

these categories by using the UP or DOWN button or 

the PAGE UP or PAGE DOWN button, press SELECT 

when you find the correct name. Choose CUSTOM to 

type in your own names.

NOTE 

The Auxiliary labels AIR BLOWER and FILL 

LINE have an automatic 30 minute runtime.  

To change this setting, refer to the DEVICE 

RUNTIME feature.

 

If DIP switch S1-1,2 or 3 are on, auxiliaries 1, 

2 and 3 are labeled CLEANER, LOW SPEED 

and SPILLOVER respectively and cannot be 
relabeled.

4.1.5 

Set Freeze Protection

MENU/HELP > SYSTEM SETUP > FREEZE PROTECT > SET 

TEMP VALUE > SELECT FREEZE PROTECT DEVICE

Highlight MENU/HELP and press SELECT. Highlight 

SYSTEM SETUP and press SELECT. Highlight 

FREEZE PROTECT and press SELECT. Use the UP 

or DOWN button to change the temperature. Once the 

temperature is set press the SELECT button to move to 

the next screen to assign freeze protection to a selected 

piece of equipment. Highlight a device and press 

SELECT. “X” means the device has been assigned. 

NOTE

  The filter pump is always assigned to freeze 

protection.

4.1.6 

Assign JVAs

MENU/HELP > SYSTEM SETUP > ASSIGN JVAs > SELECT JVA

Highlight MENU/HELP and press SELECT. Highlight 

SYSTEM SETUP and press SELECT. Highlight 

ASSIGN JVA and press SELECT. Highlight the JVA 

you wish to assign and press SELECT. 

NOTE

  If a solar sensor is installed, the solar JVA will 

automatically be assigned and will be marked 

as USED.

4.1.7 

Seasonal Adjust

MENU/HELP > SYSTEM SETUP > SEASONAL ADJ > SELECT 

FILTRATION/SPRINKLERS/FILL LINE/CLEANER

Highlight MENU/HELP and press SELECT. Highlight 

SYSTEM SETUP and press SELECT. Highlight 

SEASONAL ADJ and press SELECT. Use the 

UP/DOWN BUTTON TO choose FILTRATION, 

SPRINKLERS, FILL LINE, and CLEANER, then press 

SELECT. 

NOTE

  FILL LINE will be displayed on the screen only 

if an AUX has been assigned to fill the label. 

CLEANER will be displayed on the screen only 

if DIP switch S1-1 is ON. AQUAPURE will be 

displayed only if a chlorine generator is attached 

to the system.

Содержание AquaLink M8

Страница 1: ...his product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death I...

Страница 2: ...8 Installation Manual DATE OF INSTALLATION INSTALLER INFORMATION INITIAL PRESSURE GAUGE READING WITH CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL CONTROL PANEL MODEL SERIAL NUMBER NOTES EQUIPMENT I...

Страница 3: ...aults and General Modes 24 4 5 PDA Installation 24 4 6 PDA Handheld Remote System Defaults and General Modes 26 4 7 PDA Handheld Remote On Off Menu 27 4 8 Pool Heat 28 4 9 Spa Heat 28 4 10 Solar Heat...

Страница 4: ...res between 38 C 100 F and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes b Since excessive water te...

Страница 5: ...of a spa or hot tub The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas Water temperature in excess of 38 C 100 F may be hazardous to your...

Страница 6: ...mp Sensors Two 2 JVAs for pool spa combo systems 2 2 Electrical Specifications Power Supply 240 VAC 50 Hz 2 5 A Contact Rating Mains Voltage 25 A 3HP 240 VAC 1500 Watts Incandescent Extra Low Voltage...

Страница 7: ...Page 7 AquaLink M8 Installation Manual Dimensions 122...

Страница 8: ...spa consult the Jandy Pro Series Valve Actuator Installation and Operation Manual to ensure that the JVAs are synchronized and rotate properly Please consult the Jandy Valve Plumbing Manual for furthe...

Страница 9: ...Pool Cleaner Plumbing Heater Booster Pump Pool Return Spa Return Spa Make up Check Valve Pool Intake Spa Intake Filter Pump Heater Pool Return Spa Return Non Booster Pump Pool Cleaner Plumbing Spa Mak...

Страница 10: ...a Pump Pool Pump Pool Intake Spa Intake Spa Return Pool Return Pool Filter Spa Filter Check Valve optional Check Valve Optional NOTE When connecting to the AquaLink RS plug the JVAs into the Intake Re...

Страница 11: ...appropriate wire for equipment 3 2 2 Bonding the Power Center Install a bonding lug to the power center enclosure Connect the bond lug using a 8 solid copper core wire to an approved earth ground an...

Страница 12: ...two cables running to each of the red 4 pin connectors on the power center PCB See Figure 7 3 2 4 Wiring the Pentair Pump The Pentair IntelliFlo VF LCD control panel is disabled when communicating wi...

Страница 13: ...cuitry of 120 VAC or greater do not connect to the green 10 pin terminal bar Instead connect the heater to a high voltage relay in the power center and plug the spare relay into the electric heater re...

Страница 14: ...eration Manual Cam Setting Chart for proper settings 3 5 1 JVA Mounting Positions C Remove these four 4 screws for Standard Position A B Common Port Figure 12 Standard Plumbing Water flow into or out...

Страница 15: ...ews Remove Locking Knob and Handle Remove the 4 Large Phillips Head Screws 3 Turn the actuator over to see into the actuator shaft There are four 4 teeth inside of the shaft Align with the smallest sl...

Страница 16: ...s 1 Turn OFF actuator power Unscrew the locking knob by turning the knob counterclockwise Remove the locking knob and valve handle 2 Remove the four 4 Phillips head screws that secure the actuator lid...

Страница 17: ...he power center to the location of the control panel see Figure 10 Sheetrock Surface Mount Box OneTouch PCB Faceplate Figure 22 OneTouch Surface Mount Installation 4 Pull the 4 conductor cable through...

Страница 18: ...onto the back of the OneTouch PCB Place the OneTouch PCB back into the Flush Mount Housing Insert the screws with rubber washers and hand tighten Do not overtighten Snap the faceplate into place This...

Страница 19: ...t the POOL speed setting during its filtration cycle Example 1 The total length of the filtration cycle is to be from 8am to 5pm So program the FILTER PUMP to turn on at 8am and to turn off at 5pm 2 T...

Страница 20: ...P or DOWN button or the PAGE UP or PAGE DOWN button press SELECT when you find the correct name Choose CUSTOM to type in your own names NOTE The Auxiliary labels AIR BLOWER and FILL LINE have an autom...

Страница 21: ...MP SPA PUMP NOT INSTALLED NOT INSTALLED AUX PUMP NOT INSTALLED If the system is not going to control a variable speed pump then leave the application set to NOT INSTALLED If the system is going to con...

Страница 22: ...h S1 1 is ON then the default label for this preset is CLEANER Anytime the cleaner mode is turned on the pump will run at the speed setting of this preset On a combo system if dip switch S1 1 is OFF t...

Страница 23: ...ected On a dual equipment system when a pump is configured as a SPA PUMP the default label for preset 1 is SPEED1 4 3 16 Preset 2 On a dual equipment system when a pump is configured as a SPA PUMP the...

Страница 24: ...tem is in service or time Out mode the system will default to auto In previous firmware versions the system would default to last mode of operation ATTENTION Special Note to Startup Person The AquaLin...

Страница 25: ...ge Raceway 6 Min To Ground Level Blower or Other Equipment Low Voltage Cable High Voltage Raceway Transceiver J Box 8 Min 18 Channel RF Transceiver A 3 Yellow 1 Red 2 Black 4 Green 1 4 6 DETAIL A Figu...

Страница 26: ...he PCB in the Transceiver J box slide the Learn Switch to LEARN ON See Figure 32 6 On the Handheld Remote display screen a prompt will appear with instructions to slide the J box Learn Switch out of L...

Страница 27: ...t on or off The ALL OFF mode will turn off equipment that has been turned on by any means manual or pre programmed This includes any of the heater enables that were on unless in use by the Maintain fu...

Страница 28: ...SELECT Highlight POOL HEAT and press SELECT Use the UP DOWN arrow keys to set the desired temperature and press SELECT EQUIPMENT FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 MORE O...

Страница 29: ...OFF OFF OFF OFF OFF ON OFF OFF OFF ENA OFF OFF EQUIPMENT FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 MORE NOTE If no Solar Sensor is installed EXTRA AUX will appear as a menu item...

Страница 30: ...OLAR HEAT POOL LIGHT AUX 2 AUX 3 MORE ON OFF OFF OFF OFF OFF OFF OFF PLEASE WAIT CYCLING TO CHOSEN COLOR SET COLOR ALPINE WHITE SKY BLUE COBALT BLUE CARIBBEAN BLU SPRING GREEN EMERALD GREEN EMERALD RO...

Страница 31: ...ith your installer The speed of a variable speed pump can be adjusted from the EQUIPMENT ON OFF screen In the example below the SPEED PRESET 3 is adjusted to 2750 RPM 4 14 1 To adjust the Variable Spe...

Страница 32: ...F SELECT EQUIPMENT ON OFF ALL OFF ADD PROGRAM DELETE CHANGE CHILL MODEL SENSORS REMOTES ERRORS MODE POOL SPILLOVER COLOR LIGHTS ASSIGN TO AUX SELECT EQUIPMENT SELECT DEVICE SELECT DEVICE SELECT LABEL...

Страница 33: ...F SPA POOL ADD PROGRAM DELETE CHANGE CHILL MODEL SENSORS REMOTES ERRORS SELECT EQUIPMENT SET SPA ONETOUCH ON OFF SPA MODE CLEAN MODE ALL OFF ON OFF EQUIPMENT ON OFF SELECT EQUIPMENT ON OFF ALL OFF ONE...

Страница 34: ...art number and revision letter displayed is for the CPU Board indicating which model System locked up Microprocessor locked Turn off power to the system and turn back on Programs do not run at the cor...

Страница 35: ...Aux 3 Relay Cool Down Normal Spare Aux Pool Mode See Manual Gas Heater 1 2 3 4 5 6 7 8 Note that S1 3 and S1 6 operate with Pool and Spa Combo Only 230 240 VAC Power 10 Amp 10 Amp 10 Amp 10 Amp 10 Am...

Страница 36: ...de switch is pressed the return valve actuator will rotate to spa circulation Because the intake valve actuator does not rotate the spa will fill with water and overflow into the pool NOTE Leave AUX 3...

Страница 37: ...peed filter pump Filter pump circuit becomes High Speed 3 AUX3 any equipment AUX3 Spa Spillover effect Combination controls only 4 Heater cool down operates Heater cool down disabled 5 Normal operatio...

Страница 38: ...pment No change 4 Heater cool down operates Heater cool down disabled 5 Normal operation Factory adjustment when this switch is on tem perature delays are eliminated and solar tem perature is displaye...

Страница 39: ...There is no Heat Pump OFF Sensor installed Connected In this configuration there is Solar Heating and there is Solar Priority There is Heat Pump There is Heat Pump Priority ON No sensor installed Not...

Страница 40: ...ght 2 Light 3 Light Back Light Basement Light Beach Light Bedroom Light Bug Light Cabana Light Color Wheel Light Deck Light Dock Light Drive Light East Light Entry Light Equipment Light Fan Light Fenc...

Страница 41: ...Page 41 AquaLink M8 Installation Manual NOTES...

Страница 42: ...Page 42 AquaLink M8 Installation Manual NOTES...

Страница 43: ...Page 43 AquaLink M8 Installation Manual NOTES...

Страница 44: ...nal S A S U used under license All trademarks referenced herein are the property of their respective owners 2019 Zodiac Pool Systems Inc H0665000 REVB Fluidra Group Australia 219 Woodpark Road Smithfi...

Отзывы: