Slide cleat into the
slot opening, thread
screw through the boss
and into the cleat.
Boss
Sheet Rock
(1/2” or 5/8”
with a 4”
square cutout)
Flush
Mount
Housing
OneTouch
PCB
Faceplate
Figure 24. OneTouch Flush Mount Installation
3.6.2
Flush Mount OneTouch Installation
1. With the aid of the homeowner, find the best
location for the control panel.
2. Place the flush mount box in the location chosen
for the control panel. Level the box and trace
around the outside of the box with a pencil. Cut the
hole being careful not to oversize.
3. Route the 4-conductor cable from the power center
to the indoor control panel.
4. Pull the 4-conductor cable through the hole in the
wall and the hole in the flush mount box. Push the
flush mount box into the hole in the wall with the
correct orientation (see Figure 24).
5. Depending on what size sheet rock (16mm or
13mm), determine which side of the cleat is to be
facing you (see Figure 25).
6. Insert a screw through the screw boss (see Figure
28). Put a cleat into the top “U” shaped hole. Hand
tighten the screw and repeat the process for the
bottom cleat.
7. Wire the 4-conductor cable to the red, 4-pin
terminal bar. Push the 4-pin terminal bar onto the
back of the OneTouch PCB. Place the OneTouch
PCB back into the Flush Mount Housing. Insert the
screws with rubber washers and hand tighten.
Do
not overtighten
. Snap the faceplate into place.
This side
faces towards
you for 5/8”
sheetrock.
This side
faces towards
you for 1/2”
sheetrock.
Figure 25. Cleat Orientation
3.6.3
Multiple AquaLink M8 OneTouch
Control Panel Installation
The AquaLink M8 allows each system to support a
maximum of 4 indoor control panels (see Figure 14).
The control panels may be wired “in series” starting
from the first control panel (solid lines), or wired “in
parallel” from the AquaLink M8 power center (dotted
lines), or any combination of the two. In other words,
any number of indoor control panels and/or power
centers can be connected by means of the red, 4-pin
terminal bar in any combination of “series” or “parallel”
wiring.
NOTE
Minimum wire size should be 22 AWG. If more
than one control panel is installed, or the length
of run is more than 100M, larger wire should be
used.
22 AWG
Minimum
Figure 26. Installing Multiple OneTouch Control
Panels
3.6.4
AquaLink M8 OneTouch
™
Control
Panel Jumper Settings
Move these jumpers only when installing more than one
control panel on a system (see Figure 27). The jumpers
are used to give each control panel a unique system
address. When replacing an existing control panel,
change the jumper settings to match those on the one
being replaced.