Page 13
AquaLink
®
M8 | Installation Manual
Page 12
AquaLink
®
M8 | Installation Manual
TO CONTROLLER
R B Y G
1 2 3 4
MUST BE
OFF
FOR AQUALINK RS
PUMP ADDRESS
MUST BE
ON
FOR STAND ALONE UI
4-Position DIP Switch
TO CONTROLLER
R B Y G
1 2 3 4
MUST BE
OFF
FOR AQUALINK RS
PUMP ADDRESS
MUST BE
ON
FOR STAND ALONE UI
Jandy ePump
TM
DC
Figure 9. Zodiac
®
ePump
™
and VS Pump Dip Switch
3.2.6
Zodiac ePump DIP switch settings
As shown in Figure 13, the 4-position dip switch is
located at the rear of the Zodiac ePump. This dip switch
serves two functions - it determines what type of control
will be used with the pump and it selects the pump
address.
The SW 1 (switch 1) and SW 2 are turned ON if the
pump is to be controlled by a stand alone controller or
OFF if the pump is to be controlled by the AquaLink.
SW 1
SW 2
CONTROL
OFF
OFF
AquaLink
ON
OFF
OFF
ON
ON
ON
Stand Alone
The SW 3 and SW 4 are turned ON/OFF to
select the pump address.
SW 4
SW 3
PUMP No.
OFF
OFF
1
OFF
ON
2
ON
OFF
3
ON
ON
4
3.3 Heater Connection
The heater connection section applies to all heaters or
heat pumps with thermostatic circuitry of 24 VAC or
less.
NOTE
If you are connecting a heater with thermostatic
circuitry of 120 VAC or greater, do not connect
to the green, 10-pin terminal bar. Instead
connect the heater to a high voltage relay in the
power center and plug the spare relay into the
electric heater relay socket on the power center
PCB.
3.3.1
Other Brands Heater and Pump
Connections
To set up heater connections on heaters and heat
pumps made by other manufactures, please refer to the
Installation Manual provided with these heaters and heat
pumps.
3.4 Temperature Sensors
1. Drill hole in pipe between filter pump and filter
and install the
water temperature sensor
per
instructions (make certain the o-ring is in place).
2. Install
air temperature sensor
outside the power
center can, not in direct sunlight and away from
motors and other heat sources.
3. Install
solar temperature sensor
(optional)
adjacent to solar panels.
NOTE
If a solar sensor is not installed, the solar button
can be labeled and used as an extra auxiliary.
4. Run the wire to the power center, through the low
voltage raceway. Cut off excess wire. Strip the
wire jacket back 15cm, then strip each wire 6mm.
Connect sensor wires to the green, 10-pin terminal
bar (see Figure 10).
10 9 8 7 6 5 4 3 2 1
Water
Temperature
Sensor
Freeze/Air
Temperature
Sensor
Solar
Temperature
Sensor
Green 10-Pin Terminal Bar
Figure 10. Temperature Sensor
Wiring for a Pool/Spa
Combination