Page 23
AquaLink
®
M8 | Installation Manual
Page 22
AquaLink
®
M8 | Installation Manual
On pool/spa only systems the default label is TEMP2.
When the pump is running and the heater set point
TEMP2 is enabled, then the pump will run at this preset.
4.3.13 Preset 7:
If the system is in the SOLAR HEAT mode or the
HEAT PUMP mode then the pump will run at this preset
speed. If the system is not configured for solar heat or a
heat pump then the default label will be SPEED7.
4.3.14 Preset 8:
When the In-Floor clean mode is enabled and the pump
is running, it will be running at this preset speed.
4.5.7 Default Preset Speed Labels (Dual
Equipment)
When a pump is configured to be either a POOL PUMP
or a SPA PUMP, the speed presets will be labeled as
shown in the table below. The presets can be relabeled
but the operation of the speeds may be changed by
doing so.
Default Labels and Speeds when Pumps
are configured as POOL PUMP and SPA PUMP
(Dual Equipment Systems)
PRESET #
POOL PUMP
SPA PUMP
SPEED
1
POOL
SPEED1
1725
2
SPEED2
SPA
2750
3
SPEED3 or
CLEANER
(if dip S1-1 is on)
SPEED3
2750
4
SPEED4
SPEED4
2750
5
POOL HEAT
SPEED5
2250
6
SPA HEAT
SPA HEAT
2250
7
SOLAR HEAT
(if dip S1-7 is on)
or HEATPUMP
(if dip S2-7 is on)
or SPEED7
SPEED7
2750
8
INFLOOR
SPEED8
2750
4.3.15 Preset 1:
On a dual equipment system when a pump is configured
as a POOL PUMP, the default label for preset #1 is
POOL. This label is tied to the pool filtration mode.
Anytime the pool pump is supposed to turn on, this
preset is selected.
On a dual equipment system when a pump is configured
as a SPA PUMP, the default label for preset #1 is
SPEED1.
4.3.16 Preset 2:
On a dual equipment system when a pump is configured
as a SPA PUMP, the default label for preset #2 is SPA.
This label is tied to the spa filtration mode. Anytime
the spa pump is supposed to turn on, this preset is
selected.e.
On a dual equipment system when a pump is configured
as a POOL PUMP, the default label for preset #2 is
SPEED2.
4.3.17 Preset 3:
For the pool pump, if dip switch S1-1 is ON, then the
default label for this preset is CLEANER. Anytime
the cleaner mode is turned on the pump will run at the
speed setting of this preset. If dip switch S1-1 is OFF,
then the default label for this preset is SPEED3.
For the spa pump the default label is SPEED3.
4.3.18 Preset 4:
The default label is SPEED4.
4.3.19 Preset 5:
For the pool pump the default label is POOL HEAT.
When the pool heater is enabled the pump will run at
this speed.
For the spa pump the default label is SPEED5.
4.3.20 Preset 6:
For the pool pump the default label is SPEED6.
For the spa pump the default label is SPA HEAT. When
the spa heater is enabled the pump will run at this speed.
Preset 7:
For the pool pump, if the system is in the SOLAR
HEAT mode or the HEAT PUMP mode then the
pump will run at this preset speed. If the system is not
configured for solar heat or a heat pump then the default
label will be SPEED7.
For the spa pump the default label is SPEED7.
4.3.21 Preset 8:
For the pool pump, when the In-Floor clean mode is
enabled and the pump is running, it will be running at
this preset speed.
For the spa pump the default label is SPEED8.