ZKTECO White LCD Serials User Manual
Press
OK
to enter.
If serial number of user time period is 1 or 20, then
Use group
time
period
automatically change to “
No
”.
GroupVerType is set as NO, so user use type (individual Verifying type)
as the following figure.
TZ 2 20
TZ3
Type FP
GroupVer type N
User 00002Opt
▲
Belong to GRP 2
User GRP TZs N
TZ1 1
User’s serial number is 00002.
1) User’s belonged grouping is “2”, it uses user time period and does not
use group time period, i.e. it is effective in time periods of 1 and 20.
When user wants to use group time period, then select “
Yes
”. In user
time period, serial number of group time period will be automatically
assigned the value of serial number of group time period. Contrariwise,
if user wants to use user time period, just directly modify the serial
number in user time period and
Use group
time period
will
automatically change to “
No
”.
2) User use individual Verifying type, namely use fingerprint verifying
type.
4.5.3.4 Access Combination
Unlocking combination is the direct representation of controlling
unlocking. E.g., if user wants all registered users cannot unlock, then the
user can set all 10 unlocking combinations to null.
- 52 -
Содержание White LCD Series
Страница 2: ......