4.5.3 Function Description
4.5.3.1 Time Period
Time period is the minimum time period unit of Access Options. Whole
system can be defined with maximum 50 time periods. And 7 time
regions (i.e. one week) can be set in each time period. Each time region
is effective time period in 24 hours of a day. Each user can own
maximum 3 time periods. Relationships among these three time periods
are “OR”. It is effective as long as the time to verify that can meet one
of these three time periods. Each time period format is
HH:MM-HH:MM and its format is according to 24-hour mode and
accurate to minute.
End-time less than start-time (E.g. 23:57-23:56) represents all-day
forbidden. If the end-time larger than start-time (E.g. 00:00- 23:59)
represents the access setting takes effective in this range.
Effective time period for user to unlock: All-day open (00:00-23:59) or
end-time larger than start-time in time period.
Note:
System defaults that time period of serial number 1 is all-day
open, the new registered user belongs to the group1 and own the
serial number1 time period, so the new registered user default can
unlock door.
Setting operations:
Enter “Define TZ” and screen displays as follows:
Define TZ
Time Period No
1
ESC
OK