ZKTECO White LCD Serials User Manual
function does not exist in the fingerprint device which is used in
T&A and Simple Access Control.
Enter the Access Option, press
OK
, the following appears:
Access Comb
Lock 150
Dsen Delay 10
Dsen. Mode N
Dsen.Alarm 30
Dress Options
AlarmCnt
GroupVerType
Access Option
▼
►
Define TZ/TP
User Acc Opts
GRP TZ/TP Define
Main function in Access Options:
1. Define TZ:
Is the definition of everyday Time period that can unlock door
in one week;
2. User Access Option:
Is the definition User Group, User’s Time
period and unlock comb.
3. Group Time Period:
Is used to set group unlocking time.
4. Access Comb
(Unlocking combination)
:
Defines different unlocking
combinations, each combination is composed of different groups.
5. Lock
(Time duration of lock drive)
:
Fingerprint scanner controls the
time to open electronic lock.
6. Dsen.Delay:
Some segment time which begin after open door just
begin alarm.
7. Dsen.Mode:
There are three option that is none (NONE), normal
open (NO), normal close (NC). The none means the door Sensor doesn’t