12. Appendix
When master machine is set as “out anti-pass back”, if user wants to
come in and go out normally, his recent record must be “in”, or he
cannot go out. Any “out” record will be refused by “anti-pass back”. For
example, a user’s recent record is “in”, his second record can be “out” or
“in”. His third record is based on his second record. Out record and in
record must match (Note: If customer has no record before, then he can
come in but cannot go out).
When the master machine is set as “in anti-pass back”, if the user wants
to come in and go out normally, his recent record must be “out”, or he
cannot go out. Any out record will be “anti-pass back refused” by the
system (Note: If the customer has no former record, then he can go out,
but cannot come in).
When the master machine is set as “out-in anti-pass back”, if the user
wants to come in and go out normally, if his recent record is “out” and
“in”, then his next record must be “in” and “out”.
Operations:
【
operation
】
1. Select model
Master machine: Machine with Wiegand in function, except for F10
reader
Slave machine: Machine with Wiegand Out function
2. Menu setting
Anti-pass back
There are three options: out anti-pass back, in anti-pass back, and non
anti-pass back.
Out anti-pass back: Only user’s last record is in-record, can the door be
open.
In anti-pass back: Only user’s last record is out-record, can the door be
open.