15.4
Reset
Allocating the parameters of the ZAdyn4B with the standard values or customer-speci
fi
c system data.
The works setting is made by a numeric input in the
Statistics/RESET
menu.
Reset-functions:
Reset-No.
Effect
77
Pre-parametrised ZAdyn4B:
Parameters are assigned cus-
tomer-speci
fi
c system data
Standard ZAdyn4B:
Parameters are assigned default values
based on the available hardware
90
deleting of:
•
Parameter
•
Error list
•
Error messages
Parameters are assigned default values based on the available
hardware
99
deleting of:
•
Parameter
•
Error list
•
Error messages
Parameters are assigned default values based on the available
hardware
CAUTION!
Attention!
In synchronous motors, the parameters for the encoder offset (ENC_OFF) are set to 0 during a reset.
If a value was entered beforehand for ENC_OFF, after performing a reset either an encoder-offset
alignment must be carried out or the old values for ENC_OFF must be entered!
Operating the motor without encoder offset alignment can cause uncontrolled motor movements!
CAUTION!
Attention! - Reset 90 and 99
Any pre-parametrisation carried out by ZIEHL-ABEGG for the ZAdyn4B will be lost if a reset is
performed.
The parameters are allocated the factory settings. These do not correspond to the pre-con
fi
g-
uration!
Information
You can only start-up again after entering the parameters in the
Motor name plate
,
Encoder & BC
,
Installation
,
Control system
and
Monitoring
menus (see "Commissioning" chapter).
15.5
Memory card
The following functions are feasible when using a memory card (MMC card or SD card) in the X-MMC
card slot:
•
Software-Update (see "Memory card / Software update" chapter)
•
Storing parameters (see "Parameter list / Menu Memory Card / Function SAV_PAR" chapters)
•
Loading parameters (see "Parameter list / Menu Memory Card / Function LOD_PAR" chapters)
•
Storing parameter lists, error lists and parameters with allocation of the ZAdyn4B serial number
(see chapter "Parameter list / Menu Memory Card / Function SAV_ALL")
•
Continuous recording of operating curves with an MMC recorder and saving the measurements in
standstill (see "Parameter list / Menu MMC recorder" chapter)
Information
The LED of the ZAdyn4B lights up in blue when the ZAdyn4B is accessing the memory card.
Original operating instructions
ZAdyn4B 110-180
Special functions
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
161/200
1
5
S
p
e
c
ia
l
fu
n
c
ti
o
n
s
Содержание ZA dyn 4B 110
Страница 194: ...Original operating instructions ZAdyn4B 110 180 Enclosure R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 194 200 ...
Страница 197: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 197 200 16 Enclosure ...
Страница 198: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 198 200 ...
Страница 199: ...16 Enclosure Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 199 200 ...