5.13.2
Technical data X-OUT
Short-circuit-proof
no*
Min. switching capacity
5 mA / 12 VDC
Max. switching capacity
2 A / 250 VAC
Cable cross section
max. 2,5 mm
²
CAUTION!
Attention!
* In order to protect the relay contacts, switched inductivities must be provided with an external
suppressor circuit (suppressor diode, RC element).
5.13.3
Terminal assignment X-OUT
The output assignments can be con
fi
gured. The con
fi
guration can be implemented by:
•
Presetting the used control system (assignment corresponding to the control requirements)
•
Free con
fi
guration
Implement con
fi
guration of the digital outputs in the
Control system\CONFIG
menu.
Please refer to the "Parameter list/Control menu" chapter for a description of the individual parameters
The output assignments dependent on the con
fi
guration:
Con
fi
guration
Outputs
O11 - O14
O21 - O24
O31 - O34
O41 - O44
O51-- 54
00:Free
Fault
MB_Brake
RB
V < V_G1
STO-Info
01:ZA_IO
Fault
MB_Brake
RB
V < V_G1
STO-Info
03:BP_IO
Fault
MB_Brake
RB
V < V_G1
STO-Info
08:KN_IO
Fault
MB_Brake
RB
V < V_G1
STO-Info
11:NL_IO
Fault
MB_Brake
RB
V < V_G1
STO-Info
13:SS_IO
Fault
MB_Brake
RB
V < V_G1
STO-Info
15:ZA_BIN
Fault
MB_Brake
RB
V < V_G1
STO-Info
16:WL_IO
Fault
MB_Brake
RB
V < V_G1
STO-Info
21:ST_IO
Fault
MB_Brake
RB
V < V_G1
STO-Info
24:CSILVA
Fault
MB_Brake
RB
V < V_G1
STO-Info
25:X_BIN
RB
MB_Brake
V=O
Fault
STO-Info
27:MAS_BIN
Fault
MB_Brake
RB
Off*
STO-Info
30:KS_IO
Fault
MB_Brake
RB
V < V_G1
STO-Info
31:KL_IO
Fault
MB_Brake
RB
Evac.Dir.
STO-Info
32: S_SMART
Fault
MB_Brake
RB
SD
STO-Info
5.14
DCP / CAN interface (X-DCP, X-CAN)
As an alternative to the conventional wiring, it is possible to control the ZAdyn4B via DCP or CANopen
lift (see chapter "Serial communication").
Information
The X-DCP and X-CAN connection terminals are standard parts of the ZAdyn4B.
5.14.1
DCP
•
Use a shielded cable for the connection. The shielding must be grounded on the inverter side.
•
Con
fi
gure the connection between the ZAdyn4B and the control system without additional terminal
points.
•
The maximum line length is 50 m.
Original operating instructions
ZAdyn4B 110-180
Electrical installation
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
37/200
5
E
le
c
tr
ic
a
l
in
s
ta
l-
la
ti
o
n
Содержание ZA dyn 4B 110
Страница 194: ...Original operating instructions ZAdyn4B 110 180 Enclosure R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 194 200 ...
Страница 197: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 197 200 16 Enclosure ...
Страница 198: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 198 200 ...
Страница 199: ...16 Enclosure Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 199 200 ...