Parameter descriptions for digital inputs
Parameter
Function
Explanation
00:Free
Function not assigned
Activating the input is noneffective
01:RF
Controller enable
Enabling the ZAdyn4B. The input must be activated during the
entire journey.
02:RV1
Direction preset UP
Travel direction "UP"
03:RV2
Direction prest DOWN
Travel direction "DOWN"
04:V1
Positioning speed
Speed to position the car to the stop point
05:V2
Intermediate speed
If necessary, the intermadiate speed for normal travel
06:V3
Travel speed V_3
High travel speed for normal travel
07:VZ
Readjustment speed
Speed for readjustment. Has precedence above all other
speeds!
08:V4
Additional speed 1
Additional speed for inspection and return operation
09:V5
Additional speed 2
Additional speed for inspection and return operation
10:V6
Additional speed 3
Additional speed for inspection and return operation
11:V7
Additional speed 4
Additional speed for inspection and return operation
12:PARA2
Switchover to 2nd parameter set
2nd parameter set is activated
13:BIN0
Binary input 0
Speed default through binary coding
Standard-con
fi
guration
14:BIN1
Binary input 1
Speed default through binary coding
Standard-con
fi
guration
15:BIN2
Binary input 2
Speed default through binary coding
Standard-con
fi
guration
16:DIR
Direction default
Default for direction of travel when using one input
1 signal: Direction of travel "UP"
0 signal: Direction of travel "DOWN"
17:v=0
Hold speed 0
When the motor brake is open, speed 0 is controlled
18:RF+RV1
Controller travel direction UP
Controller enable and travel direction "UP" are triggered with
one input
19:RF+RV2
Controller travel direction
DOWN
Controller enable and travel direction "DOWN" are triggered with
one input
20:BR1
Brake monitoring 1
Brake monitoring with unsing the input terminal X-IN
21:BR2
Brake monitoring 2
Brake monitoring with unsing the input terminal X-IN
22:BR3
Brake monitoring 3
Brake monitoring with unsing the input terminal X-IN
23:BR4
Brake monitoring 4
Brake monitoring with unsing the input terminal X-IN
24:XBIN0
Binary input 0
Free binary assignment
Speed default through binary coding
Free binary assignment
25:XBIN1
Binary input 1
Free binary assignment
Speed default through binary coding
Free binary assignment
26:XBIN2
Binary input 2
Free binary assignment
Speed default through binary coding
Free binary assignment
27:MBIN0
Binary input 0
Con
fi
guration Masora
Speed default through binary coding
Con
fi
guration Masora
28:MBIN0
Binary input 1
Con
fi
guration Masora
Speed default through binary coding
Con
fi
guration Masora
29:MBIN0
Binary input 2
Con
fi
guration Masora
Speed default through binary coding
Con
fi
guration Masora
30:STANDBY2
Standby 2
Switching the ZAdyn4B to Standby 2 function to save energy
31:STEP+
Touch mode for special applications
Positive change
32:STEP-
Touch mode for special applications
Negative change
33:PFU_BR
BR monitoring for option PFU+BR
Functional monitoring of brake resistor when using a brake
resistor in conjunction with power recuperation unit
34:HY_UP
Direction UP at hydraulic elevator with
Bucher aggregate type Saturn ALPHA
The input functions RF+RV1+V1 are activated simultaneously
when the input is activated
only in ZAdyn HY
Original operating instructions
ZAdyn4B 110-180
Parameter list
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
79/200
1
0
P
a
ra
m
e
te
r
lis
t
Содержание ZA dyn 4B 110
Страница 194: ...Original operating instructions ZAdyn4B 110 180 Enclosure R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 194 200 ...
Страница 197: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 197 200 16 Enclosure ...
Страница 198: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 198 200 ...
Страница 199: ...16 Enclosure Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 199 200 ...