Power2 - - - - - - - - - -
13
ERR_EXT U. OC: ...
SRC_APP. UCE_P: ...
SRC_MOP. UCE_M: ....
Page 12: Power2
Cause for excess current malfunction
Line 2:
ERR_EXT: Excess current message (display is not saved; point is only displayed if excess
current is present
U: Overvoltage error in the DC-link (voltage higher than 850 V DC)
OC: Overcurrent was detected by the current sensors (incorrect phase is indicated by letters
U V Z)
Line 3:
SRC_APP: Excess current is detected by the application processor.
UCE_P: Error in positive current path in power stage (faulty phase is displayed)
Line 4:
SRC_MOP: Excess current is detected by the motor management processor.
UCE_M: Error in negative current path in power stage (faulty phase is displayed)
During normal operation, no points and phase displays (U V W) should be active
During a malfunction, the displays remain active until the next travel command (with the
exception of ERR_EXT)
Bus Info 1 - - - - - - -
14
Info: xx
0101 / 010106 de
Load: 77% - 12.3A
Page 14: Bus Info 1
Information about the control system
Line 2:
Manufacturer
Line 3:
Software version of control system
Software date of the control system
Operating language set in the control system, display according to ISO639
The operating language of the frequency inverter is automatically adapted.
Line 4 (only with DCP4):
Load in % (0% = cabin empty)
Load-dependent start torque current
Bus Info 2 - - - - - - -
15
B01..4... G....4...
S.1....6. 100
RF UP V_3* MTW
Page 15: Bus Info 2
Online-display
Line 2:
Command and speed bytes
B= command byte
G= speed byte
Line 3:
Status byte
S= Statusbyte
Current operating state of the ZAdyn4B
Line 4:
Display of the actual travel commands:
RF: Controller enable
Travel direction
controlled travel speed
MTW: Motor temperature pre-warning, displayed at overtemperature (for ZAdyn4)
See chapter "Serial Communication / DCP (Drive Control & Position)" for further information
about DCP operation.
Original operating instructions
ZAdyn4B 110-180
Parameter list
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
101/200
1
0
P
a
ra
m
e
te
r
lis
t
Содержание ZA dyn 4B 110
Страница 194: ...Original operating instructions ZAdyn4B 110 180 Enclosure R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 194 200 ...
Страница 197: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 197 200 16 Enclosure ...
Страница 198: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 198 200 ...
Страница 199: ...16 Enclosure Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 199 200 ...