Error no.
Error text
Error cause
M S
781
Quick. during travel
Cause:
The signal at the digital input con
fi
gured for
“
V=0
”
is activated during
travel
Remedy:
Check the triggering of "V=0"
●
●
799
RF: Interruption
Cause:
The signal at the digital input con
fi
gured for the
“
RF
”
controller enable
function has been switched off during travel
Remedy:
Check the triggering of "RF"
Check the safety circuit
●
800
CAN: Timeout
Cause:
Error in Velocity mode: Heartbeat from the control missing or not
received at the set intervals
Error in the Position mode: Heartbeat from the control and/or rotary encoder
missing or is not received at the set intervals
Remedy:
Check CAN connections
Check that the heartbeat for the corresponding devices is set correctly
●
820
CAN: Illegal State
Cause:
The control is sending CAN control words at an impermissible time or
in the wrong sequence
Remedy:
Check that the control has the latest software version
●
●
821
CAN: Position Error
Cause:
During travel at a speed greater than 10 cm/s the shaft position does
not change within 200 ms (CAN Position mode)
Remedy:
Check the CAN absolute encoder in the shaft
Check the traction conditions of the drive (traction sheave)
●
●
831
CAN:Timeout Dis. Op.
Cause:
The control does not issue the
“
Disable Operation
”
command within
the time
“
T_CMD
”
entered in the
“
CAN
”
menu when stopping
Remedy:
Check the time for
“
T_CMD
”
Check compatibility of the control with the CAN speci
fi
cation CiA-417
Check the fault counter for changes during travel in the
“
Bus Info 4
”
info menu
For sporadic occurrence: Check EMC-compatible installation (screening, etc.),
termination of CAN bus (terminating resistors)
●
832
CAN:Timeout Shutdown
Cause:
The control does not issue the
“
Shutdown
”
command within the time
“
T_CMD
”
entered in the
“
CAN
”
menu when stopping
Remedy:
Check the time for
“
T_CMD
”
Check compatibility of the control with the CAN speci
fi
cation CiA-417
Check the fault counter for changes during travel in the
“
Bus Info 4
”
info menu
For sporadic occurrence: Check EMC-compatible installation (screening, etc.),
termination of CAN bus (terminating resistors)
●
833
CAN:Timeout Dis.Vol.
Cause:
The control does not issue the
“
Disable Voltage
”
command within the
time
“
T_CMD
”
entered in the
“
CAN
”
menu when stopping
Remedy:
Check the time for
“
T_CMD
”
Check compatibility of the control with the CAN speci
fi
cation CiA-417
Check the fault counter for changes during travel in the
“
Bus Info 4
”
info menu
For sporadic occurrence: Check EMC-compatible installation (screening, etc.),
termination of CAN bus (terminating resistors)
●
840
CAN:Enc.Info missing
Cause:
The
“
Position conversion
”
object (0x641F) has not been written to the
frequency converter by the control
Remedy:
Check that the control has the latest software version
●
Original operating instructions
ZAdyn4B 110-180
Error diagnosis
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
143/200
1
3
E
rro
r
d
ia
g
n
o
s
is
Содержание ZA dyn 4B 110
Страница 194: ...Original operating instructions ZAdyn4B 110 180 Enclosure R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 194 200 ...
Страница 197: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 197 200 16 Enclosure ...
Страница 198: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 198 200 ...
Страница 199: ...16 Enclosure Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 199 200 ...