12.2.2
Parameterization
(1) The following prerequisites must be present:
The direction of travel of the car is downwards with
Standard
DCP
24 V signal on input con
fi
gured to
"RV2"
Command byte 1, Bit 4 has 1-sig-
nal
Detection of voltage drop
Con
fi
gure digital input in the
Control system
menu to
PARA2
.
Control
|
-
"
f_I08
PARA2
|
-
"
PARA2
Function I_08
In case of a power failure, the input con
fi
gured for 24 VDC is actuated in order to inform the frequency
inverter that a switchover to parameter set 2 is necessary.
(3) Inform the open loop control about the permissible direction of travel (optional):
Standard
DCP
In the
Control
menu, con
fi
gure the digital output to
Evac.Dir
Status byte 2, Bit 2 = 0
R
Car is lighter than coun-
terweight
Evacuation trip will be carried out upwards!
Status byte 2, Bit 2 = 1
R
Car is heavier than
counterweight
Evacuation trip will be carried out downwards!
Control
|
-
"
f_O4
Evac.Dir
|
-
"
Evac.Dir
Function O4
Contact open
R
Car is lighter than counterweight
Evacuation trip will be carried out upwards!
Output closed
R
Car is heavier than counterweight
Evacuation trip will be carried out downwards!
(4) Evacuation type default
Con
fi
gure the parameter
F_PARA2 = EVA. 3*AC
in the
Parameter set 2
menu.
Parameter set 2
|
-
"
F_PARA2 EVA.3*AC
|
-
"
EVA.3*AC
Function parameter set 2
(5) Copying the parameters:
In the menu
Parameter set 2 / COPY
, select the function
PARA->2
. After copying, the parameter is
once again OFF.
Parameter set 2
|
-
"
COPY
Off
|
-
"
Para1
R
2
Copy parameter
Information
The power failure detection and type of evacuation must be parameterised before copying the
parameters. It is possible to reduce the required power during the evacuation. The values for speed
and acceleration have to be adjusted in the 2.nd parameter set for this.
Original operating instructions
ZAdyn4B 110-180
Emergency evacuation
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
124/200
Содержание ZA dyn 4B 110
Страница 194: ...Original operating instructions ZAdyn4B 110 180 Enclosure R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 194 200 ...
Страница 197: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 197 200 16 Enclosure ...
Страница 198: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 198 200 ...
Страница 199: ...16 Enclosure Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 199 200 ...