15.13.6
Motor brakes test
The function interrupts the safety circuit during travel. The distance covered by the cabin before
coming to standstill is shown in the display.
Information
The function is only possible in connection with CAN activation.
Perform motor brakes test
Powersection
-> Checks
ZA-Intern
Select
"Checks"
menu
Checks
|
-
"
SCY_EN
OFF
|
-
"
ON
Enable tests
Select parameter
"SCY_EN"
Enter "SCY_EN=On"
Checks
|
-
"
SCY_MB
OFF
|
-
"
ON
Engine brakes test
Select parameter
"SCY_MB"
Switch on motor brakes test with "SCY_MB=ON"
Give travel command up with empty cabin
Interrupt safety chain
Difference in cabin posi-
position
+ 13mm
Display distance up to standstill
Original operating instructions
ZAdyn4B 110-180
Special functions
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
185/200