Parameter
Designation
Value range
Factory set-
ting
TYP
Enter the motor's type of connection
Star
Delta
Star
ENC_TYP
Enter the type of encoder used
EnDat/SSI:
Absolute rotary encoder
Position information is transmitted either via SSI (synchronous
serial interface) or EnDat protocol
ERN1387:
Absolute encoder
Position information is transmitted by analog signal
Hiperface:
absolute encoder
Codeface:
absolute encoder
BiSS-C:
: Absolute value encoder with BiSS-C interface
TTL sine:
5 V rotary encoder with sine signal
TTL rect.:
5 V rotary encoder with rectangle signal
HTL 10-30 V:
10-30 V rotary encoder with rectangle signal
No ENC
: Open loop operation
EnDat/SSI
HTL 10-30V
TTL square
TTL Sine
Hiperface
Codeface
ERN1387
No ENC.
BiSS-C
Depends on
con
fi
gured
motor type
ENC_INC
Enter encoder resolution (pulses/revolution)
64 ... 11000
BC_TYP
Enter the used brake resistor or brake chopper
BR11:
Brake resistor type BR11-A
BR50:
Brake resistor type BR50
BR50+BR25:
parallel connection of BR25 and BR50
BR50+BR50:
parallel connection of 2 pieces BR50
BRxx:
Brake resistor external product
PFU:
Power Feedback Unit
PFU+BR11:
Power Feedback Unit + Brake resitor type BR11
PFU+BR11:
Power Feedback Unit + Brake resitor type BR17
PFU+BR11:
Power Feedback Unit + Brake resitor type BR25
PFU+BR11:
Power Feedback Unit + Brake resitor type BR50
BR09-1:
Brake-Resistor Type BR09-1
BR14:
Brake resistor type BR14
BR100:
Brake resistor type BR100
PFU+BRxx:
Power Feedback Unit + Brake resitor external prod-
uct
2*BR100:
parallel connection of 2 pieces BR100
3* BR100:
Parallel circuit of three BR100
BR17-1:
Brake resistor type BR17
BR25-1:
Brake resistor type BR25
BC25:
Brake-Chopper type BC25
BC50:
Brake-Chopper type BC50
BC100:
Brake-Chopper type BC100
ZArec:
ZArec feedback unit
BR11
BR50
BR50+BR25
BR50+BR50
BRxx
PFU
PFU+BR11
PFU+BR17
PFU+BR25
PFU+BR50
BR09-1
BR14
BR100
PFU+BRxx
2* BR100
3* BR100
BR17
BR25
BC25
BC50
BC100
ZArec
BR17
V*
Enter the installation rated speed
0.00 ... 10.00 m/s
1.00
n*
Motor speed at V*
MOD_n = direct:
direct input of the motor speed at V*
MOD_n = calculate:
Calculates the speed of the motor depend-
ent on: V*; __D; __iS;__; __i1 and __i2
0.1 ... 6000 rpm
0
__D
Enter the diameter of the traction sheave
0.06 ... 1.50 m
0.50
__iS
Enter the installation's type of suspension
1:1
2:1
3:1
4:1
5:1
6:1
7:1
8:1
1:1
__i1
Entry of
i1
gearbox ratio
i1:i2
1 ... 650
38.00
Original operating instructions
ZAdyn4B 110-180
Parameter list
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
69/200
1
0
P
a
ra
m
e
te
r
lis
t
Содержание ZA dyn 4B 110
Страница 194: ...Original operating instructions ZAdyn4B 110 180 Enclosure R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 194 200 ...
Страница 197: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 197 200 16 Enclosure ...
Страница 198: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 198 200 ...
Страница 199: ...16 Enclosure Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 199 200 ...