Time-dependent deceleration with reached traveling speed
RF
Controller enable
V_1
Positioning speed
V_2
Intermediate speed
V_3
Travel Speed
RV1 / RV2
Direction default
RB
Controller ready
MB_Brake
Mechanical brake
11.7.2
Deceleration when traveling speed has not been reached
6
When the switch off point for the traveling speed is reached, the con
fi
gured
fi
nal speed
V_3 is not reached.
Deceleration is initiated
7
Travel at positioning speed V_1.
8
Positioning speed V_1 is switched off.
Motor continues to decelerate.
9
Speed 0
Output MB is switched off
Brake must operate immediately
The motor continues to be fed with current
10
The current to the motor is switched off
Output RB is switched off
The inputs of the STO function must be deactivated immediately ("0" signal) or motor
contactors de-energized.
Original operating instructions