Information
The parameters required for operation without a rotary encoder (open loop) are only displayed for
C_MOD=U/f
. The parameters are described in the chapter "Operation without a rotary encoder".
10.14
Parameter set 2 menu
A second parameter set can be stored in the frequency inverter. This can be used for:
•
Emergency evacuation
•
Normal travel with changed parameter values
•
Parameter back-up
Parameter
Designation
Value range
Factory set-
ting
f_PARA2
Function allocation of parameter set 2
Locked:
2nd parameter set is blocked
2nd parameter set:
Activation of 2nd parameter set
EVAC 3:
Emergency evacuation with evacuation module EVAC
3
EVA. 3*AC:
Emergency evacuation through three-phase current
emergency-generator
EVA.1*AC:
Emergency evacuation with UPS
UPS:
Emergency evacuation by UPS with reduced power
Locked
2nd parameter set
EVAC 3
EVA. 3*AC
EVA. 1*AC
UPS
Locked
U_ACCU
Accu nominal voltage
Con
fi
guring the rated voltage of the rechargeable battery during
evacuation with evacuation unit EVAC 3 ("f_PARA2=EVAC 3B",
see "Emergency evacuation" chapter)
100 ... 565 V
120
P_UPS
Max. Load UPS
Con
fi
guring the available power of the UPS during evacuation
with UPS ("f_PARA2=UPS", see "Emergency evacuation" chap-
ter)
0.0 ... 70.0 kW
1.0
R_U20
Stator resistor
Enter the resistor of the stator of themotor with "f_PARA2=UPS"
0.0 ... 9.99 Ohm
1.00
STOP
Stop function to improve the positioning accuracy in the evacua-
tion mode "f_PARA2=UPS"
ON:
- Brake is closed when the switch point for V_1 is closed.
- Brake is closed when the residual path con
fi
gured in S_STOP
has been reached (only for DCP02/04
OFF:
Stop function deactivated
On
Off
Off
Copy
Copy parameter set
OFF:
Function deactivated
PARA1->2:
copies the data from 1st parameter set into the 2nd
parameter set
Off
Para 1->2
Off
10.15
Statistic menu
All statistical data can be called up in the
Statistics
menu. The data will be retained even after the
ZAdyn4B has been switched off. Reading out the error list and deleting the error memory are
described in the chapter "Error diagnosis".
Information
Not all parameters are visible when the
Statistic
menu is opened in the basic level.
Parameter
Designation
Value range
Factory
setting
visible in
the basic
level
ST_LST
Error list
Cannot be set
-
X
ST_H
Operating hours
Cannot be set
-
X
ST_DRV
Number of trips
Cannot be set
-
X
ST_HDRV
Number of travel hours
Cannot be set
-
X
Original operating instructions
ZAdyn4B 110-180
Parameter list
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
88/200
Содержание ZA dyn 4B 110
Страница 194: ...Original operating instructions ZAdyn4B 110 180 Enclosure R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 194 200 ...
Страница 197: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 197 200 16 Enclosure ...
Страница 198: ...Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 198 200 ...
Страница 199: ...16 Enclosure Original operating instructions ZAdyn4B 110 180 R TBA15_01 GB 2014 Index 005 Part No 00163453 GB 199 200 ...