It is possible to set a 

header

, text string of up to 10 characters that identifies the Configuration page 

and that will be shown in the left upper side of the display when accessing that page. 

The adjustable parameters of ZAS are the following: 

 

Contrast:

  to  adjust  the  contrast  level  of  the  ZAS  display  (value  between  0  and  20).  To 

modify this level, just  press the button corresponding to the Contrast in the touch panel (the 

first one on the left). The current contrast level is then shown; to increase it, just press the up 

arrow button and to decrease it, the down arrow button. 

 

Light

  to  adjust  the  luminosity  level  of  the  ZAS  display  (value  between  1  and  10).  To 

modify this level, just press the button corresponding to the Luminosity in the touch panel (the 

first one on the right). The current luminosity level is then shown; to increase it, just press the 

up arrow button and to decrease it, the down arrow button. 

 

Time:

 to set the clock time of the controller. Format is "hh:mm". To modify this, just press 

the button corresponding to Time in the touch panel (the second one on the left). The current 

time will be shown; the first thing to be modified is the hour, by means of the Arrow buttons. 

Then, via the OK button or the Hour button itself, the focus goes to the Minutes, that can be 

adjusted with the Arrow buttons. To confirm the new hour value, just press the OK button or 

the Time button. 

Note:

 

On bus power losses and depending on length, a delay in the internal time of the device 

may happen. This must be kept in mind and corrected once the power supply is restored.

 

 

Calibration:

  when  pressing  this  button,  ZAS  goes  into  the  calibration  page.  See  the 

calibration  sequence  in  figure  1.3.  A  re-calibration  may  be  necessary  when  the  initial 

calibration  has  not  been  carried  out  properly  after  downloading  the  application  so  presses 

cannot be done in the centre of the button. 

 

Programming LED:

 when programming the physical address of the device, it is possible 

to  enter  the  programming  mode  directly  by  short-pressing  this  button.  This  feature  avoids 

having  to  access  the  rear  side  of  the  panel  to  physically  push  the  “Programming  Button”. 

While the programming LED is active, the LED associated to this button will be ON. To leave 

the  programming  mode,  just  short-press  this  button  again  (the  programming  LED  and  the 

button LED will be switched off). 

 

Reset: 

a long press of at least of 3 seconds will be required on this button to reset ZAS. 

All the stored statuses will be reset to the default values. 

Содержание Roll-ZAS

Страница 1: ...Roll ZAS KNX Room Controller ZN1VI TPZAS Program version 1 1 Manual edition a PRODUCT MANUAL...

Страница 2: ...Parameterization 14 3 1 Default configuration 14 3 2 General 15 3 3 Pages 21 3 3 1 Pages 1 4 23 a Pair buttons 24 b Individual buttons 28 3 3 2 Configuration page 30 3 3 3 Security page 32 3 3 4 Indic...

Страница 3: ...s in the factory defaults Possibility to enter the programming mode from the buttons of the touch panel 6 Section 2 4 note added on the use of the remote control 13 Section 3 3 screenshot updated info...

Страница 4: ...te shutters lights scenes etc Figure 1 1 ZAS Room Controller The most relevant features of ZAS are shown below 1 8 back lighted display with 128 x 64 pixels Temperature sensor with thermostat function...

Страница 5: ...erent actions according to the ETS configuration Moreover starting with version 1 1 it is also possible to use the central area of the touch panel as an additional binary control providing the user wi...

Страница 6: ...touch interface itself In the factory default state after being connected to the KNX bus and prior to any type of download the device will show a certain interface with almost no functionality at all...

Страница 7: ...screen will indicate the button to be pressed each time only if a text string associated to this process has been previously configured in ETS under General Labels See section 3 2 Figure 1 3 Calibrat...

Страница 8: ...nd Screensaver All of them are explained in detail in section 3 3 Pages of this manual The access and navigation through the configured pages is explained in section 2 3 Inputs ZAS incorporates 2 opto...

Страница 9: ...ee section 3 3 Moreover with the arrow buttons it is possible to increase decrease one by one the values of contrast illumination and time of the Display from the Configuration page as well as establi...

Страница 10: ...h the corresponding object 2 3 PAGE NAVIGATION The Roll ZAS application has an intuitive user interface that allows through the use of pages knowing at any time the chosen functionality for every butt...

Страница 11: ...ery enabled button can be intuitively identified Moreover to identify which button has been pressed the corresponding icon will be drawn with the colour inverted for example in Figure 2 2 the button t...

Страница 12: ...ter 45 seconds of inactivity ZAS will automatically switch to page 1 only if the screensaver has not been enabled or has not been triggered yet 2 4 ZAS IR CONTROL An optional remote control is availab...

Страница 13: ...omfort Standby and Economy they allow directly setting the special climate mode Comfort Standby and Economy It is necessary that these modes have been implemented in ETS in order to active them from t...

Страница 14: ...n the following sections there is a detailed explanation about each of the different functionalities of MAXinBOX 16 in ETS 3 1 DEFAULT CONFIGURATION This section shows the default parameterization the...

Страница 15: ...o configure the screensaver configuration Inputs destined to enable and configure each input of the controller individually Thermostats destined to enable and configure each thermostat of the controll...

Страница 16: ...nsaver mode or keeping the default levels these values are Normal luminosity 10 and Screensaver luminosity 7 To customize this luminosity level the following options appear Figure 3 4 Luminosity optio...

Страница 17: ...a LED whenever the value 1 is received This option may be useful when connecting ZAS to a presence detector so that when it detects movement in the room to be controlled it sends the value 1 through...

Страница 18: ...through the object General Central button while unlocked Lock IR as well option to lock the remote control at the same time as the touch panel Yes In this case presses over the remote will not be take...

Страница 19: ...emote control is not possible but it is by pressing the same buttons in the touch panel Presses over the other action buttons will provoke an automatic switch to page 1 and the corresponding action wi...

Страница 20: ...ommunication object is enabled IR Special mode which will send to the remote thermostat the value of the button pressed 1 for Comfort 2 for Standby and 3 for Economy IR locking locking the remote cont...

Страница 21: ...nal Sensor Overheating and Internal Sensor Overcooling which will indicate with the value 1 if the corresponding limit has been exceeded It is necessary to define the overheating or the overcooling te...

Страница 22: ...t button will send an ON increase order while a pressing on the left button sends an OFF decrease order or the opposite The pages to be enabled and configured are Pages 1 4 Configuration page Security...

Страница 23: ...er to Page 1 but they are exactly the same for the rest of the pages 2 4 Figure 3 9 Page 1 Configuration First of all the Header parameter is shown where it is possible to establish an identifying tex...

Страница 24: ...dependent both LEDs lighting both LEDs will stay on or off simultaneously depending on the value of the object Dimmer 3 communication objects are enabled Px Byz Light On Off a 1 bit object to switch o...

Страница 25: ...op shutter and one 1 byte object Px Byz Shutter position which sets the position of the shutter in percentage at any time 0 Top 100 Bottom In the Display between both buttons the status sent from the...

Страница 26: ...buttons will make the different labels alternate in the display sending to the bus the numeric value associated to the final label The first press will always show the current value of the control A c...

Страница 27: ...Byz Temperature indicator which will receive the value 20 and 95 C to be represented in the Display every time a button of the pair is pressed Multimedia control Only available for pair buttons in Pag...

Страница 28: ...Release under this mode the KNX bus will be sent a binary value 0 or 1 through the 1 bit object Px Byz Binary control Hold while the corresponding button is held and the same value or another one whe...

Страница 29: ...the status object of the light actuator so that the LED lighting status is always up to date Timer this functionality allows sending to the KNX bus a binary value 1 or 0 or a scene number at a certain...

Страница 30: ...n is performed directly from the Display by long pressing the corresponding button In this configuration mode a digital clock is shown with the hh mm format where to configure the time at which the va...

Страница 31: ...thing to be modified is the hour by means of the Arrow buttons Then via the OK button or the Hour button itself the focus goes to the Minutes that can be adjusted with the Arrow buttons To confirm the...

Страница 32: ...fies the Security page and that will be shown in the left upper area of the display when accessing that page The first parameter to be configured is the number of the security levels to perform being...

Страница 33: ...h panel in execution time The configured security level may be modified in Execution time through the Security page in the Display see Figure 3 12 Figure 3 12 Security page Display Buttons 1 4 allow h...

Страница 34: ...lue received by the Ind x 1 byte indicator object Scaling shows in the Display the value received by the Ind x Scaling indicator object Enumeration allows the definition of up to 6 discrete values wit...

Страница 35: ...of inactivity greater than 45 seconds ZAS will switch to Page 1 automatically Moreover the luminosity level of the Display can be configured being the possible options Always lighting the Display rema...

Страница 36: ...nsor it is necessary to select the actions to perform on the arrival of one falling edge and on the arrival of one rising edge Figure 3 14 Input Switch Sensor The available options are Rising edge for...

Страница 37: ...new 1 bit communication object Ix Lock is deployed making it possible to lock and unlock the corresponding input with one 1 or one 0 respectively During the time the input is locked orders received f...

Страница 38: ...enths of a degree Temperature protection permits enabling overheating overcooling or both protections Depending on the chosen protection one or two communication objects will be enabled Ix Overheating...

Страница 39: ...n the behaviour and the ETS parameterization of them please consult the specific documentation Motion Detector available at http www zennio com 3 5 THERMOSTATS The possibility to controlling up to 2 i...

Страница 40: ...nce simulation After enabling the presence simulation in ETS two new 1 bit communication objects will be shown Sim Presence Simulation and Sim Simulation Channel The first one allows activating or dea...

Страница 41: ...hich the presence simulation begins or finishes provided that the functionality has been enabled by a 1 through the object Sim Presence simulation Note The start and the finish times must be different...

Страница 42: ...0 1 Minus Plus Down Up Left Right Stop Play Icons for pair buttons they are the same as for individual buttons but they appear grouped in pairs The left one will be shown on the left button of the pa...

Страница 43: ...e float value BUTTONS 6 37 1 bit 1 byte 2bytes I O Several 0 1 0 255 20 95 C 0 100 0 6553 5 P1 By Individual Buttons Page 1 Several Functionings P1 Byz Pair Buttons Page 1 Several Functionings 38 69 1...

Страница 44: ...Indifferent Indifferent General Touch block 1 Block 0 Nothing 0 Block 1 Nothing 140 1 bit I W 0 1 Indifferent Indifferent General Touch unblock 0 Unblock 1 Nothing 1 Unblock 0 Nothing 141 1 bit O T 0...

Страница 45: ...rcool 157 158 1 bit O TR 0 1 0 Last Ix Overheating 1 Overheat 0 No Overheat 160 161 1 bit O RT 0 1 State dependant State dependant Ix Probe error 1 Error 0 No Error 216 218 1 bit O T 0 1 0 0 Ix Shortc...

Страница 46: ...ndby Economy or Protection 0 Nothing 1 Trigger Tx Special Mode x x Comfort Standby Economy or Protection 0 Off 1 On 176 177 1 bit I W 0 1 0 Last Tx Window status input 0 Closed 1 Opened 178 179 1 bit...

Страница 47: ...2 203 1 bit O RT 0 1 As Param As Param Tx ON OFF Status 0 Off 1 On 204 206 1 bit O RT 0 1 0 Last Tx Control variable Cool PI control PWM Tx Control variable Cool 2 point control 205 207 1 bit O RT 0 1...

Страница 48: ...48 ZENNIO TECHNICAL DOCUMENTATION BECOME USER http zennioenglish zendesk com TECHNICAL SUPPORT...

Отзывы: