1-byte unsigned integer.
Enables the 1-byte object "[Px][Byz] 1-byte indicator",
which will receive the value (0-255) to be represented in the Display every time a button
of the pair is pressed.
Scaling.
Enables the 1-byte object "[Px][Byz] Scaling indicator", which will receive
the value (0-100%) to be represented in the Display every time a button of the pair is
pressed.
2-byte unsigned integer.
Enables the 2-byte object "[Px][Byz] 2-byte indicator",
which will receive the value (0-65535) to be represented in the Display every time a
button of the pair is pressed.
Temperature.
Enables the 1-byte object "[Px][Byz] Temperature indicator", which will
receive the value (-20 and 95ºC) to be represented in the Display every time a button of
the pair is pressed.
Multimedia control:
(
Only available for pair buttons in Page 4
).
The 1-bit communication object "[P4][Byz] Binary control" is enabled, which will be set to value
"0" or "1", depending on the button that is pressed. Moreover, associated to the multimedia
control is the 14-byte object "[P4][Byz] String indicator", through which a text string of up to 14
characters is received, which will be represented in the Display, in the middle of the two
buttons of the pair.
Take into account:
After a KNX bus failure, the values received through the 14-byte object
will be deleted. It is necessary to wait 15-20 seconds before accessing page 4 so that this
process is complete and there are no remaining residual characters.