1-6
INTRODUCTION / INSTRUMENT SETUP
REV. B 02/03 PN 51680-1
HUMPHREY FIELD ANALYZER
II -
i
series
Easy operation
Sophisticated instrumentation need not be complicated. The HFA II offers a number of features
intended to make the instrument easier to use:
• Touch screen design speeds data input.
• Menu and icon commands simplify operation.
• On-screen video eye monitor is standard on all models.
• Confirmation screens reduce unintentional data loss.
• A keyboard and trackball or mouse can be connected to the HFA II as optional data
input devices.
Speedy testing
Carl Zeiss Meditec’s SITA™ testing strategies allow precise visual field measurements
with unprecedented speed. With the SITA strategies, users can obtain visual field information in
half the time it takes using conventional testing algorithms without compromising accuracy
.
SITA represents the very latest in autoperimetry technology and it is only available with your
Humphrey Field Analyzer II.
Sophisticated data
The Humphrey Field Analyzer’s statistical software, STATPAC™, provides immediate expert
analysis with STATPAC™
system analysis of visual field test results. With STATPAC you can analyze test results at the time
of examination, store test results and analyze them at your convenience, or recall previously
stored tests to analyze for comparative purposes.
STATPAC includes several exclusive features to help you identify visual field change:
• Using results from a single test, STATPAC can point out suspicious areas that otherwise
might not be evident until subsequent tests were done.
• STATPAC can identify areas that look suspicious but which, in fact, compare favorably
with normals data.
• Using results from a series of tests, STATPAC provides a highly sensitive and informative
analysis of changes in the patient’s visual field over time.
• The Glaucoma Hemifield Test (GHT) compares points in the superior and inferior
hemifields to provide a plain language analysis of test results.
• The HFA II provides separate databases for STATPAC analysis. These include databases
for SITA and Blue-Yellow perimetry, in addition to the well-established databases for
Full Threshold and FastPac test results.
• Another database consisting of stable glaucoma patients is used with the Glaucoma
Change Probability Analysis for following change in the progress of the disease. This
analysis is only available with Full Threshold testing.
1.htp
3/14/03, 2:41 PM
6
Содержание HUMPHREY 720i
Страница 1: ...HUMPHREY FIELD ANALYZER II i series USER S GUIDE Model 720i Model 740i Model 745i Model 750i...
Страница 4: ......
Страница 26: ...1 18 INTRODUCTION INSTRUMENT SETUP REV B 02 03 PN 51680 1 HUMPHREY FIELD ANALYZER II i series...
Страница 116: ...6 8 TEST RELIABILITY REV B 02 03 PN 51680 1 HUMPHREY FIELD ANALYZER II i series...
Страница 208: ...10 20 CUSTOM TESTING REV B 02 03 PN 51680 1 HUMPHREY FIELD ANALYZER II i series...
Страница 284: ...12 14 CARE AND CLEANING REV B 02 03 PN 51680 1 HUMPHREY FIELD ANALYZER II i series...
Страница 327: ......
Страница 328: ......