All Rights Reserved. Copyright © 2010, Yokogawa Electric Corporation
GS 05P02D41-01EN Mar.14,2016-00
n
Block Diagram
Output limiter
Manual operation
Manual preset output
Input error preset output
Preset output
AUTO
When sensor burnout occurs
Normal
MAN
RUN
RESET
SP limiter
PV
Input type
Input unit
Input range/scale
PV input bias
PV input filter
Output limiter
BS
FL
CNT
ALG
SPH, SPL
UNIT
IN
RH, RL
SDP
SH, SL
EPO
OH, OL
OH, OL
OLMT
PO
MPON
OT
Equipped as standard
For option code /HA
Heater break alarm
HAL2
HAL1
Heater break
alarm 1
Heater break
alarm 2
Current or voltage pulse
Relay
Current
OUT
OUT
RET
OUT retransmission output
O1RS
RET retransmission output
RTS
* After the control output terminal is specified by the parameter OT,
other current output terminals can be used as retransmission output.
Output terminal assignment
Control computation
(Current when retransmission output)
RS-485, Ethernet, PROFIBUS-DP, DeviceNet, CC-Link
PV input
Equipped as standard
Terminal
Parameter
Function
Analog signal
Contact signal
Front panel key
Legend
PV display
SP display
Input ladder calculation program (signal goes to the control computation as is when without ladder program). For ladder program, see the LL50A Parameters Setting Software User’s Manual.
Com.
Program pattern
Local target setpoint
Reset
TSP
S.PID
PTNO.
TIME
TM.RT
L.PID
LSP
LOC
RUN
RST
RESET/RUN switch
DI45
DI44
DI43
DI42
DI41
DI2
DI1
DI3
Contact inputs
DI41 to DI45 are equipped when option code /X4.
Start of program operation
when DI changes from OFF to ON.
Stop of program operation
when DI changes from OFF to ON.
Start of local-mode operation
when DI changes from OFF to ON.
Program pattern
selection
(Select a
number during a
RESET state.)
RST
A/M
LOC
RUN
AL3
AL2
AL1
PV event 1
PV event 2
Alarm 1
Alarm 2
Time event 1
Time event 2
Time event 3
Time event 4
DO13
DO12
DO11
DO14
DO15
PV event, Time event, Alarm
DO11 to DO15 are equipped
when option code /Y1.
Output ladder calculation program (signal goes to the output as is when without ladder program). For ladder program, see the LL50A Parameter Setting Software User’s Manual.
Analog input bias
Analog input filter
A.BS
A.FL
Содержание UP35A
Страница 3: ......
Страница 15: ...Blank Page...
Страница 35: ...Blank Page...
Страница 37: ...Blank Page...
Страница 47: ...Blank Page...
Страница 229: ...Blank Page...
Страница 251: ...Blank Page...
Страница 317: ...Blank Page...
Страница 387: ...Blank Page...
Страница 409: ...Blank Page...
Страница 411: ...Blank Page...