![YASKAWA Varispeed V7 Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/yaskawa/varispeed-v7/varispeed-v7_instruction-manual_3554366097.webp)
96
Note: 1. The Product Code depends on the Inverter capacity. For example, the
Product Code for the CIMR-V7NA20P2 is 3001.
2. The
characters contain the capacity portion of the Inverter’s
model number. For example, if the Inverter is a CIMR-V7NA21P5,
the
characters will contain 21P5.
Message Router Object (Class 02 Hex)
The Message Router object has a function that separates the DeviceNet
communications information. Both explicit messages and I/O messages
are always assigned functions through this object. The Message Router
object itself performs only internal processes and it does not have data
that is exchanged externally.
• Supported Services
01
05
Status
Indicates the
Inverter's commu-
nications status.
---
0001
OK
---
Word
06
Serial
Number
Indicates the seri-
al number of the
Inverter communi-
cations.
---
Depends
on prod-
uct.
OK
---
Long
07
Product
Name
Indicates the mod-
el number.
• V7N
A
(See note 2.)
---
Capacity
characters
(See note
2.)
OK
---
String
08
State
Indicates the
Inverter's status.
• 3:
Inverter
ready.
• 4:
Inverter
error occurred.
---
03
OK
---
Byte
Service
Code
(Hex)
Service Name
Description
0E
Get_Attribute_
Single
Returns the contents of the specified
attribute.
In-
stance
At-
tribute
Name
Contents
Setting
Range
Factory Set-
ting (Hex)
Read
Write
Size