![YASKAWA Varispeed V7 Скачать руководство пользователя страница 253](http://html1.mh-extra.com/html/yaskawa/varispeed-v7/varispeed-v7_instruction-manual_3554366253.webp)
252
• 200 V Class Single-phase
• 400 V Class 3-phase
* Sets the value of the motor resistance for one phase.
No.
Name
Unit
Factory Setting
-
Inverter Ca-
pacity
kW
0.1 kW 0.25 kW 0.55 kW 1.1 kW 1.5 kW 2.2 kW
-
3.7 kW
n036
Motor Rated
Current
A
0.6
1.1
1.9
3.3
6.2
8.5
-
14.1
n105
Torque Com-
pensation Iron
Loss
W
1.7
3.4
4.2
6.5
11.1
11.8
-
19
n106
Motor Rated
Slip
Hz
2.5
2.6
2.9
2.5
2.6
2.9
-
3.3
n107
Line to Neu-
tral (per
Phase)*
Ω
17.99
10.28
4.573
2.575
1.233
0.8
-
0.385
n108
Motor Leakage
Inductance
MH
110.4
56.08
42.21
19.07
13.4
9.81
-
6.34
n110
Motor No-load
Current
%
72
73
62
55
45
35
-
32
No.
Name
Unit
Factory Setting
-
Inverter Ca-
pacity
kW
-
0.37 kW 0.55 kW 1.1 kW 1.5 kW 2.2 kW 3.0 kW 3.7 kW 5.5 kW 7.5 kW
n036
Motor Rat-
ed Current
A
-
0.6
1.0
1.6
3.1
4.2
7.0
7.0
9.8
13.3
n105
Torque
Compensa-
tion Iron
Loss
W
-
3.4
4.0
6.1
11.0
11.7
19.3
19.3
28.8
43.9
n106
Motor Rat-
ed Slip
Hz
-
2.5
27
2.6
2.5
3.0
3.2
3.2
1.5
1.3
n107
Line to
Neutral (per
Phase)*
Ω
-
41.97
19.08
11.22
5.044
3.244
1.514
1.514
0.797
0.443
n108
Motor Leak-
age Induc-
tance
MH
-
224.3
168.8
80.76
53.25
40.03
24.84
24.84
16.87
10.59
n110
Motor No-
load Cur-
rent
%
-
73
63
52
45
35
33
33
26
30