Running
1
Indicates the
Inverter’s operat-
ing status.
00: Stopped, oper-
ating in reverse, or
applying DC injec-
tion braking (Re-
verse RUN
command ON).
01: Operating for-
ward or applying
DC injection brak-
ing (Reverse RUN
command OFF).
---
00
OK
---
Byte
08
Running
2
Indicates the
Inverter’s operat-
ing status.
00: Stopped, oper-
ating forward, or
applying DC injec-
tion braking (Re-
verse RUN
command OFF).
01: Operating in
reverse or apply-
ing DC injection
braking (Reverse
RUN command
ON).
---
00
OK
---
Byte
09
Ready
Indicates the
Inverter’s prepara-
tion status.
00: Fault detected
or initializing.
01: Preparations
for operation com-
pleted.
---
00
OK
---
Byte
0A
Faulted
Indicates that the
Inverter detected
a fault.
00: Normal
01: Fault detected.
---
00
OK
---
Byte
0B
Warning
Indicates that the
Inverter detected
a warning.
00: Normal
01: Warning de-
tected.
---
00
OK
---
Byte
0C
Fault
Reset
Resets the
Inverter from fault
status.
00: ---
01: Reset fault.
00,01
00
OK
OK
Byte
0D
Fault
Code
The fault code in-
dicates which fault
was detected by
the Inverter. (See
note 3.)
---
0000
OK
---
Word
In-
stance
At-
tribute
Name
Contents
Setting
Range
Factory Set-
ting (Hex)
Read Write
Size